Schneider Electric PJA36080CU43A Molded Case Circuit Breaker 600V 800A

(No reviews yet) Write a Review
SKU:
PJA36080CU43A
UPC:
785901497134
Condition:
New
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range:
PowerPact
Mercury Free:
Yes
Quantity Per Set:
1
Sustainable Offer Status:
Green Premium product
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Product Or Component Type:
circuit breaker
Local Signalling:
overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
Height:
12.86 in
Pollution Degree:
3 IEC 60947-1
Trip Unit Technology:
electronic, ammeter, MicroLogic 5.0 A, LSI
Device Application:
distribution
Pvc Free:
Yes
Net Weight:
32 lb(US)
Warranty:
18 months
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Product Name:
PowerPact P
Environmental Disclosure:
ENVPEP2206033EN
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Circuit Breaker Application:
HACR rated
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Phase Connection:
ABC
Mounting Mode:
I-Line bracket)
Line Rated Current:
800-800 A
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Electrical Connection:
I-Line connection, line || lugs, load
Wire Stripping Length:
25 mm
Mounting Height:
9 in
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Eu Rohs Directive:
Compliant with Exemptions
Network Frequency:
50/60 Hz
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Quality Labels:
CE
Ip Degree Of Protection:
front cover IP40
Breaking Capacity Code:
J
Circularity Profile:
ENVEOLI2206033EN
Mounting Support:
bracket
Poles Description:
3P
Terminal Identifier:
AL800M23K
Width:
8.27 in
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Operation:
-2-70 °C
Control Type:
toggle
Depth:
8.05 in
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Continuous Current Rating:
1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Rohs Exemption Information:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Trip Unit Name:
MicroLogic 5.0 A
$26,214.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 5.0A trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose