Schneider Electric PJA36080U31A Molded Case Circuit Breaker 600V 800A

(No reviews yet) Write a Review
SKU:
PJA36080U31A
UPC:
7.85902E+11
Condition:
New
Control Type:
toggle
Line Rated Current:
800-800 A
Ip Degree Of Protection:
front cover IP40
Product Name:
PowerPact P
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Ambient Air Temperature For Operation:
-2-70 °C
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circuit Breaker Application:
HACR rated
Local Signalling:
overload 1 1 LED amber) || 1 trip indicator green)
Breaking Capacity Code:
J
Eu Rohs Directive:
Compliant with Exemptions
Environmental Disclosure:
ENVPEP2206033EN
Network Frequency:
50/60 Hz
Phase Connection:
ABC
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Range:
PowerPact
Rohs Exemption Information:
Yes
Depth:
8.05 in
Mercury Free:
Yes
Pvc Free:
Yes
Quantity Per Set:
1
Quality Labels:
CE
Poles Description:
3P
Net Weight:
32 lb(US)
Width:
8.27 in
Ambient Air Temperature For Storage:
-50-85 °C
Pollution Degree:
3 IEC 60947-1
Trip Unit Name:
MicroLogic 3.0
Product Or Component Type:
circuit breaker
Terminal Identifier:
AL800M23K
Mounting Support:
bracket
Mounting Mode:
I-Line bracket)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Warranty:
18 months
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Height:
12.86 in
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Wire Stripping Length:
25 mm
Electrical Connection:
I-Line connection, line || lugs, load
Continuous Current Rating:
0.8
Product Certifications:
UL || CSA || NOM
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Device Application:
distribution
Mounting Height:
9 in
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Circularity Profile:
ENVEOLI2206033EN
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Sustainable Offer Status:
Green Premium product
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric PJA36080U31A Molded Case Circuit Breaker 600V 800A
  • Schneider Electric PJA36080U31A Molded Case Circuit Breaker 600V 800A
$16,268.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose