Schneider Electric PJA36080U43A Molded Case Circuit Breaker 600V 800A

(No reviews yet) Write a Review
SKU:
PJA36080U43A
UPC:
785901264217
Condition:
New
Network Frequency:
50/60 Hz
Wire Stripping Length:
25 mm
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Poles Description:
3P
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Range:
PowerPact
Local Signalling:
overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
Width:
8.27 in
Trip Unit Technology:
electronic, ammeter, MicroLogic 5.0 A, LSI
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Ip Degree Of Protection:
front cover IP40
Depth:
8.05 in
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Circularity Profile:
ENVEOLI2206033EN
Pvc Free:
Yes
Environmental Disclosure:
ENVPEP2206033EN
Net Weight:
32 lb(US)
Sustainable Offer Status:
Green Premium product
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Eu Rohs Directive:
Compliant with Exemptions
Pollution Degree:
3 IEC 60947-1
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Continuous Current Rating:
0.8
Mercury Free:
Yes
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Circuit Breaker Application:
HACR rated
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Operation:
-2-70 °C
Mounting Mode:
I-Line bracket)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Control Type:
toggle
Ambient Air Temperature For Storage:
-50-85 °C
Mounting Height:
9 in
Product Or Component Type:
circuit breaker
Quantity Per Set:
1
Rohs Exemption Information:
Yes
Breaking Capacity Code:
J
Warranty:
18 months
Quality Labels:
CE
Phase Connection:
ABC
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Product Certifications:
UL || CSA || NOM
Device Application:
distribution
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Terminal Identifier:
AL800M23K
Electrical Connection:
I-Line connection, line || lugs, load
Product Name:
PowerPact P
Line Rated Current:
800-800 A
Trip Unit Name:
MicroLogic 5.0 A
Height:
12.86 in
Mounting Support:
bracket
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
$18,618.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 5.0A trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.