- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Environmental Disclosure:
- ENVPEP2206033EN
- Mounting Height:
- 9 in
- Mounting Mode:
- I-Line bracket)
- Mounting Support:
- bracket
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Height:
- 16.16 in
- Product Certifications:
- UL || CSA || NOM
- Net Weight:
- 32 lb(US)
- Device Application:
- distribution
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Sustainable Offer Status:
- Green Premium product
- Terminal Identifier:
- AL1200P25K
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Breaking Capacity Code:
- J
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.0, LI
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Line Rated Current:
- 1000-1000 A
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Rohs Exemption Information:
- Yes
- Mercury Free:
- Yes
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Electrical Connection:
- I-Line connection, line || lugs, load
- Local Signalling:
- 1 trip indicator green)
- Pollution Degree:
- 3 IEC 60947-1
- Eu Rohs Directive:
- Compliant with Exemptions
- Ambient Air Temperature For Storage:
- -50-85 °C
- Range:
- PowerPact
- Tightening Torque:
- 50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Circularity Profile:
- ENVEOLI2206033EN
- Wire Stripping Length:
- 30 mm
- Awg Gauge:
- 4 x AWG 3/0...500 kcmil aluminium/copper
- Product Or Component Type:
- circuit breaker
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Warranty:
- 18 months
- Pvc Free:
- Yes
- Continuous Current Rating:
- 0.8
- Trip Unit Name:
- MicroLogic 3.0
- Quality Labels:
- CE
- Ip Degree Of Protection:
- front cover IP40
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Ambient Air Temperature For Operation:
- -2-70 °C
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Phase Connection:
- ABC
- Circuit Breaker Application:
- HACR rated
- Network Frequency:
- 50/60 Hz
- Product Name:
- PowerPact P
- Poles Description:
- 3P
- Depth:
- 8.05 in
- Control Type:
- toggle
- Quantity Per Set:
- 1
- Width:
- 8.27 in