- Height:
- 12.86 in
- Local Signalling:
- overload 1 trip indicator green) || 1 trip indicator green)
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Circuit Breaker Application:
- HACR rated
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Mercury Free:
- Yes
- Terminal Identifier:
- AL800M23K
- Control Type:
- toggle
- Warranty:
- 18 months
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Net Weight:
- 32 lb(US)
- Continuous Current Rating:
- 1
- Electrical Connection:
- busbar connection, line || busbar connection, load
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Poles Description:
- 3P
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Line Rated Current:
- 800-800 A
- Circularity Profile:
- ENVEOLI2206033EN
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Product Name:
- PowerPact P
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Rohs Exemption Information:
- Yes
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Mounting Support:
- busbar
- Depth:
- 8.05 in
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.0, LI
- Product Certifications:
- UL || CSA || NOM
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Width:
- 8.27 in
- Quantity Per Set:
- 1
- Wire Stripping Length:
- 25 mm
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Pvc Free:
- Yes
- Trip Unit Name:
- MicroLogic 3.0
- Network Frequency:
- 50/60 Hz
- Mounting Mode:
- unit mount busbar)
- Product Or Component Type:
- circuit breaker
- Eu Rohs Directive:
- Compliant with Exemptions
- Quality Labels:
- CE
- Device Application:
- distribution
- Ip Degree Of Protection:
- front cover IP40
- Environmental Disclosure:
- ENVPEP2206033EN
- Range:
- PowerPact
- Pollution Degree:
- 3 IEC 60947-1
- Breaking Capacity Code:
- J
- Sustainable Offer Status:
- Green Premium product
- Ambient Air Temperature For Operation:
- -2-70 °C