Schneider Electric PJL36040CU31A Molded Case Circuit Breaker 600V 400A

(No reviews yet) Write a Review
SKU:
PJL36040CU31A
UPC:
785901677697
Condition:
New
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Eu Rohs Directive:
Compliant
Range:
PowerPact
Breaking Capacity Code:
J
Product Or Component Type:
circuit breaker
Product Certifications:
UL || CSA || NOM
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Quantity Per Set:
1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Ambient Air Temperature For Storage:
-50-85 °C
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Electrical Connection:
lugs, line || lugs, load
Ambient Air Temperature For Operation:
-2-70 °C
Depth:
8.05 in
Rohs Exemption Information:
Yes
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Quality Labels:
CE
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Height:
12.86 in
Continuous Current Rating:
1
Poles Description:
3P
Environmental Disclosure:
ENVPEP1407012EN
Product Name:
PowerPact P
Pollution Degree:
3 IEC 60947-1
Ip Degree Of Protection:
front cover IP40
Net Weight:
32 lb(US)
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green)
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Mounting Support:
lug
Terminal Identifier:
AL800M23K
Mounting Mode:
unit mount lug)
Trip Unit Name:
MicroLogic 3.0
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Circularity Profile:
ENVEOLI1407012EN
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Pvc Free:
Yes
Width:
8.27 in
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Warranty:
18 months
Line Rated Current:
400-400 A
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Circuit Breaker Application:
HACR rated
Network Frequency:
50/60 Hz
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Device Application:
distribution
Wire Stripping Length:
25 mm
Control Type:
toggle
Brochure:
View
Catalog:
View
Datasheet:
View
$22,868.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 400A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose