- Warranty:
- 18 months
- Quantity Per Set:
- 1
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Depth:
- 8.05 in
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Circuit Breaker Application:
- HACR rated
- Device Application:
- distribution
- Mounting Mode:
- unit mount lug)
- Wire Stripping Length:
- 25 mm
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Product Or Component Type:
- circuit breaker
- Line Rated Current:
- 600-600 A
- Quality Labels:
- CE
- Width:
- 8.27 in
- Product Name:
- PowerPact P
- Poles Description:
- 3P
- Control Type:
- toggle
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.0, LI
- Pollution Degree:
- 3 IEC 60947-1
- Ambient Air Temperature For Storage:
- -50-85 °C
- Breaking Capacity Code:
- J
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Eu Rohs Directive:
- Compliant with Exemptions
- Circularity Profile:
- ENVEOLI2206033EN
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Product Certifications:
- UL || CSA || NOM
- Rohs Exemption Information:
- Yes
- Pvc Free:
- Yes
- Net Weight:
- 32 lb(US)
- Sustainable Offer Status:
- Green Premium product
- Ambient Air Temperature For Operation:
- -2-70 °C
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Terminal Identifier:
- AL800M23K
- Network Frequency:
- 50/60 Hz
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Electrical Connection:
- lugs, line || lugs, load
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Mercury Free:
- Yes
- Trip Unit Name:
- MicroLogic 3.0
- Height:
- 12.86 in
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Ip Degree Of Protection:
- front cover IP40
- Continuous Current Rating:
- 0.8
- Mounting Support:
- lug
- Environmental Disclosure:
- ENVPEP2206033EN
- Local Signalling:
- overload 1 trip indicator green) || 1 trip indicator green)
- Range:
- PowerPact
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- QN-QUOTE-REQUEST:
- true