- Product Or Component Type:
- circuit breaker
- Net Weight:
- 32 lb(US)
- Circuit Breaker Application:
- HACR rated
- Rohs Exemption Information:
- Yes
- Trip Unit Name:
- MicroLogic 3.0 A
- Line Rated Current:
- 800-800 A
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Mounting Mode:
- unit mount lug)
- Range:
- PowerPact
- Terminal Identifier:
- AL800M23K
- Quality Labels:
- CE
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Product Name:
- PowerPact P
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Wire Stripping Length:
- 25 mm
- Control Type:
- toggle
- Mounting Support:
- lug
- Mercury Free:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Environmental Disclosure:
- ENVPEP2206033EN
- Continuous Current Rating:
- 0.8
- Circularity Profile:
- ENVEOLI2206033EN
- Network Frequency:
- 50/60 Hz
- Eu Rohs Directive:
- Compliant with Exemptions
- Quantity Per Set:
- 1
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Depth:
- 8.05 in
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 3.0 A, LI
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Height:
- 12.86 in
- Pvc Free:
- Yes
- Ambient Air Temperature For Storage:
- -50-85 °C
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Pollution Degree:
- 3 IEC 60947-1
- Ambient Air Temperature For Operation:
- -2-70 °C
- Width:
- 8.27 in
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Local Signalling:
- overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
- Product Certifications:
- UL || CSA || NOM
- Warranty:
- 18 months
- Breaking Capacity Code:
- J
- Sustainable Offer Status:
- Green Premium product
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Ip Degree Of Protection:
- front cover IP40
- Poles Description:
- 3P
- Device Application:
- distribution
- Electrical Connection:
- lugs, line || lugs, load
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)