Schneider Electric PJL36100CU31A Molded Case Circuit Breaker 600V 1000A

(No reviews yet) Write a Review
SKU:
PJL36100CU31A
UPC:
785901687863
Condition:
New
Mercury Free:
Yes
Breaking Capacity Code:
J
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Line Rated Current:
1000-1000 A
Terminal Identifier:
AL1200P25K
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green)
Device Application:
distribution
Ambient Air Temperature For Operation:
-2-70 °C
Range:
PowerPact
Eu Rohs Directive:
Compliant with Exemptions
Wire Stripping Length:
30 mm
Network Frequency:
50/60 Hz
Quality Labels:
CE
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
8.27 in
Quantity Per Set:
1
Pvc Free:
Yes
Mounting Support:
lug
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Control Type:
toggle
Ambient Air Temperature For Storage:
-50-85 °C
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Mounting Mode:
unit mount lug)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Product Or Component Type:
circuit breaker
Depth:
8.05 in
Poles Description:
3P
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Trip Unit Name:
MicroLogic 3.0
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Product Name:
PowerPact P
Pollution Degree:
3 IEC 60947-1
Electrical Connection:
lugs, line || lugs, load
Ip Degree Of Protection:
front cover IP40
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Net Weight:
32 lb(US)
Circularity Profile:
ENVEOLI2206033EN
Sustainable Offer Status:
Green Premium product
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Continuous Current Rating:
1
Circuit Breaker Application:
HACR rated
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Rohs Exemption Information:
Yes
Environmental Disclosure:
ENVPEP2206033EN
Product Certifications:
UL || CSA || NOM
Height:
16.16 in
Brochure:
View
Catalog:
View
Datasheet:
View
$32,147.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose