Schneider Electric

Schneider Electric PJL36100CU44A Molded Case Circuit Breaker 600V 1000A

(No reviews yet) Write a Review
SKU:
PJL36100CU44A
UPC:
785901189435
Condition:
New
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Height:
16.16 in
Device Application:
distribution
Ambient Air Temperature For Operation:
-2-70 °C
Depth:
8.05 in
Control Type:
toggle
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Rohs Exemption Information:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Quality Labels:
CE
Trip Unit Name:
MicroLogic 6.0 A
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Eu Rohs Directive:
Compliant with Exemptions
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Net Weight:
32 lb(US)
Product Certifications:
UL || CSA || NOM
Breaking Capacity Code:
J
Electrical Connection:
lugs, line || lugs, load
Ip Degree Of Protection:
front cover IP40
Wire Stripping Length:
30 mm
Mounting Mode:
unit mount lug)
Environmental Disclosure:
ENVPEP2206033EN
Range:
PowerPact
Pollution Degree:
3 IEC 60947-1
Quantity Per Set:
1
Circuit Breaker Application:
HACR rated
Ambient Air Temperature For Storage:
-50-85 °C
Sustainable Offer Status:
Green Premium product
Warranty:
18 months
Product Or Component Type:
circuit breaker
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Network Frequency:
50/60 Hz
Mounting Support:
lug
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Name:
PowerPact P
Poles Description:
3P
Mercury Free:
Yes
Circularity Profile:
ENVEOLI2206033EN
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green) || trip causes 1 trip indicator green)
Width:
8.27 in
Terminal Identifier:
AL1200P25K
Continuous Current Rating:
1
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
Pvc Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Line Rated Current:
1000-1000 A
Brochure:
View
Catalog:
View
Datasheet:
View
$36,128.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose