Schneider Electric PJL36120U33A Molded Case Circuit Breaker 600V 1200A

(No reviews yet) Write a Review
SKU:
PJL36120U33A
UPC:
785901500100
Condition:
New
Height:
16.16 in
Net Weight:
32 lb(US)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mercury Free:
Yes
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Line Rated Current:
1200-1200 A
Quantity Per Set:
1
Warranty:
18 months
Pollution Degree:
3 IEC 60947-1
Poles Description:
3P
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Product Certifications:
UL || CSA || NOM
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ip Degree Of Protection:
front cover IP40
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Eu Rohs Directive:
Compliant with Exemptions
Continuous Current Rating:
0.8
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Circuit Breaker Application:
HACR rated
Trip Unit Name:
MicroLogic 5.0
Depth:
8.05 in
Terminal Identifier:
AL1200P25K
Pvc Free:
Yes
Suitability For Isolation:
yes IEC 60947-2
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Local Signalling:
overload 1 1 LED amber) || 1 trip indicator green)
Mounting Support:
lug
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Quality Labels:
CE
Ambient Air Temperature For Storage:
-50-85 °C
Product Or Component Type:
circuit breaker
Width:
8.27 in
Network Frequency:
50/60 Hz
Utilisation Category:
category A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Environmental Disclosure:
ENVPEP2206033EN
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Device Application:
distribution
Ambient Air Temperature For Operation:
-2-70 °C
Electrical Connection:
lugs, line || lugs, load
Circularity Profile:
ENVEOLI2206033EN
Wire Stripping Length:
30 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Control Type:
toggle
Breaking Capacity Code:
J
Product Name:
PowerPact P
Range:
PowerPact
Mounting Mode:
unit mount lug)
Sustainable Offer Status:
Green Premium product
Brochure:
View
Catalog:
View
Datasheet:
View
$21,378.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose