- Quality Labels:
- CE
- Trip Unit Name:
- MicroLogic 6.0 A
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Product Certifications:
- UL || CSA || NOM
- Net Weight:
- 32 lb(US)
- Eu Rohs Directive:
- Compliant with Exemptions
- Pollution Degree:
- 3 IEC 60947-1
- Pvc Free:
- Yes
- Poles Description:
- 3P
- Utilisation Category:
- category A
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Width:
- 8.27 in
- Control Type:
- toggle
- Height:
- 16.16 in
- Mounting Support:
- lug
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Electrical Connection:
- lugs, line || lugs, load
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Circuit Breaker Application:
- HACR rated
- Line Rated Current:
- 1200-1200 A
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Environmental Disclosure:
- ENVPEP2206033EN
- Wire Stripping Length:
- 30 mm
- Ambient Air Temperature For Operation:
- -2-70 °C
- Depth:
- 8.05 in
- Warranty:
- 18 months
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Network Frequency:
- 50/60 Hz
- Quantity Per Set:
- 1
- Breaking Capacity Code:
- J
- Range:
- PowerPact
- Product Name:
- PowerPact P
- Mercury Free:
- Yes
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 6.0 A, LSIG
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Ip Degree Of Protection:
- front cover IP40
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Tightening Torque:
- 50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Ambient Air Temperature For Storage:
- -50-85 °C
- Product Or Component Type:
- circuit breaker
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-2
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Mounting Mode:
- unit mount lug)
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Continuous Current Rating:
- 0.8
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Device Application:
- distribution
- Local Signalling:
- overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
- Circularity Profile:
- ENVEOLI2206033EN
- Sustainable Offer Status:
- Green Premium product
- Terminal Identifier:
- AL1200P25K
- Awg Gauge:
- 4 x AWG 3/0...500 kcmil aluminium/copper
- Rohs Exemption Information:
- Yes