Schneider Electric PJL36120U44A Molded Case Circuit Breaker 600V 1200A

(No reviews yet) Write a Review
SKU:
PJL36120U44A
UPC:
785901863731
Condition:
New
Quality Labels:
CE
Trip Unit Name:
MicroLogic 6.0 A
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Product Certifications:
UL || CSA || NOM
Net Weight:
32 lb(US)
Eu Rohs Directive:
Compliant with Exemptions
Pollution Degree:
3 IEC 60947-1
Pvc Free:
Yes
Poles Description:
3P
Utilisation Category:
category A
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
8.27 in
Control Type:
toggle
Height:
16.16 in
Mounting Support:
lug
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Electrical Connection:
lugs, line || lugs, load
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Circuit Breaker Application:
HACR rated
Line Rated Current:
1200-1200 A
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Environmental Disclosure:
ENVPEP2206033EN
Wire Stripping Length:
30 mm
Ambient Air Temperature For Operation:
-2-70 °C
Depth:
8.05 in
Warranty:
18 months
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Network Frequency:
50/60 Hz
Quantity Per Set:
1
Breaking Capacity Code:
J
Range:
PowerPact
Product Name:
PowerPact P
Mercury Free:
Yes
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ip Degree Of Protection:
front cover IP40
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Ambient Air Temperature For Storage:
-50-85 °C
Product Or Component Type:
circuit breaker
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Mode:
unit mount lug)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Continuous Current Rating:
0.8
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Device Application:
distribution
Local Signalling:
overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
Circularity Profile:
ENVEOLI2206033EN
Sustainable Offer Status:
Green Premium product
Terminal Identifier:
AL1200P25K
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Rohs Exemption Information:
Yes
  • Schneider Electric PJL36120U44A Molded Case Circuit Breaker 600V 1200A
  • Schneider Electric PJL36120U44A Molded Case Circuit Breaker 600V 1200A
  • Schneider Electric PJL36120U44A Molded Case Circuit Breaker 600V 1200A
$25,256.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose