Schneider Electric

Schneider Electric PLM34120CU44A Molded Case Circuit Breaker 480V 1200A

(No reviews yet) Write a Review
SKU:
PLM34120CU44A
UPC:
7.85902E+11
Condition:
New
Poles Description:
3P
Warranty:
18 months
Eu Rohs Directive:
Compliant with Exemptions
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Quality Labels:
CE
Ip Degree Of Protection:
front cover IP40
Circuit Breaker Application:
HACR rated
Mounting Support:
lug
Ambient Air Temperature For Operation:
-2-70 °C
Trip Unit Name:
MicroLogic 6.0 A
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Environmental Disclosure:
ENVPEP2206033EN
Device Application:
distribution
Quantity Per Set:
1
Height:
16.16 in
Network Frequency:
50/60 Hz
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Mode:
unit mount lug)
Depth:
8.05 in
Rohs Exemption Information:
Yes
Circularity Profile:
ENVEOLI2206033EN
Net Weight:
32 lb(US)
Control Type:
toggle
Electrical Connection:
lugs, line || terminal nut, load
Width:
8.27 in
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green) || trip causes 1 trip indicator green)
Pollution Degree:
3 IEC 60947-1
Mercury Free:
Yes
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Sustainable Offer Status:
Green Premium product
Breaking Capacity Code:
L
Wire Stripping Length:
30 mm
Continuous Current Rating:
1
Breaking Capacity:
AIR 125 kA 240 V AC 50/60 Hz UL 489 || AIR 100 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 125 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 85 kA 380/415 V AC 50/60 Hz IEC 60947-2
Product Name:
PowerPact P
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Ambient Air Temperature For Storage:
-50-85 °C
[Ue] Rated Operational Voltage:
480 V AC 50/60 Hz UL 489
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Pvc Free:
Yes
Product Certifications:
UL || CSA || NOM
Range:
PowerPact
Product Or Component Type:
circuit breaker
[Ics] Rated Service Breaking Capacity:
65 kA 240 V AC 50/60 Hz IEC 60947-2 || 45 kA 380/415 V AC 50/60 Hz IEC 60947-2
Line Rated Current:
1200-1200 A
Terminal Identifier:
AL1200P25K
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Brochure:
View
Catalog:
View
Datasheet:
View
$38,270.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This break has lugs on the line side and terminal nuts on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 100kA at 480VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose