Schneider Electric QBA222004 Molded Case Circuit Breaker 240V 200A

(No reviews yet) Write a Review
SKU:
QBA222004
UPC:
785901672524
Condition:
New
Wire Stripping Length:
22 mm
Network Frequency:
50/60 Hz
Sustainable Offer Status:
Green Premium product
Line Rated Current:
200-200 A
Mounting Support:
bracket
Environmental Disclosure:
ENVPEP1406032EN
Product Name:
PowerPact Q
Ambient Air Temperature For Operation:
40-70 °C
Magnetic Tripping Current:
2400-2400 A
Warranty:
18 months
Line Rated Current:
200 A
Breaking Capacity:
10 kA 120/208 V AC 50/60 Hz UL || 10 kA 240 V AC 50/60 Hz UL
Halogen Content Performance:
Halogen free product
Trip Unit Technology:
thermal-magnetic
Phase Connection:
BC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Control Type:
operating handle
[Uimp] Rated Impulse Withstand Voltage:
8 kV UL
Circularity Profile:
N/A
Local Signalling:
1 trip indicator green)
Mechanical Durability:
1000 cycles loaded || 5000 cycles no load
Circuit Breaker Application:
HACR rated
Utilisation Category:
category A
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000
Range:
PowerPact
Depth:
3.93 in
Poles Description:
2P
Continuous Current Rating:
0.8
Product Or Component Type:
circuit breaker
Breaking Capacity Code:
B
Mounting Mode:
I-Line bracket)
Product Certifications:
UL || CSA || NOM
Height:
6.47 in
Pvc Free:
Yes
Electrical Connection:
I-Line connection, line || lugs, load
Tightening Torque:
28-28 N.m 25-150 mm² (AWG 4...300 kcmil)
Width:
3.00 in
Device Application:
distribution
Eu Rohs Directive:
Compliant with Exemptions
Mercury Free:
Yes
Mounting Height:
3 in
[Ue] Rated Operational Voltage:
240 V AC 50/60 Hz UL
Magnetic Hold Current:
1200 A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric QBA222004 Molded Case Circuit Breaker 240V 200A
  • Schneider Electric QBA222004 Molded Case Circuit Breaker 240V 200A
  • Schneider Electric QBA222004 Molded Case Circuit Breaker 240V 200A
$600.00

Description

PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT Q, 200A, 2 pole, circuit breaker has an interrupting rating of 10kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.
View AllClose