Schneider Electric RE22R1KMR Off Delay Timer Relay
Schneider Electric
$86.18
This Harmony RE22 modular single function timer can be set between 1 seconds and 300 hours, has an output rating of 5 amperes and it is 22.5 millimeters wide. This modular single function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
- Dielectric Strength:
- 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
- Supply Frequency:
- 50...60 Hz +/- 5 %
- Circularity Profile:
- ENVEOLI1401008EN
- Standards:
- IEC 61812-1 || UL 508
- Electrical Durability:
- 100000 cycles, 2 A at 24 V, DC-1 || 100000 cycles, 5 A at 250 V, AC-1
- Minimum Switching Current:
- 10 mA 5 V DC
- Ambient Air Temperature For Storage:
- -40-70 °C
- Switching Capacity In Va:
- 1250 VA
- Input Voltage:
- <= 2.4 V
- Immunity To Microbreaks:
- 10 ms
- Nominal Output Current:
- 0.208333333333333
- Maximum Switching Current:
- 0.208333333333333
- Shock Resistance:
- 15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27
- Voltage Drift:
- +/- 0.2 %/V
- Setting Accuracy Of Time Delay:
- +/- 10 % of full scale 25 °C IEC 61812-1
- Housing Material:
- self-extinguishing
- Relative Humidity:
- 95-95 % 25-55 °C
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Directives:
- 2006/95/EC - low voltage directive || 2004/108/EC - electromagnetic compatibility
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Ambient Air Temperature For Operation:
- -20-60 °C
- [Us] Rated Supply Voltage:
- 24...240 V AC/DC 50/60 Hz
- Status Led:
- Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED steady)power ON
- Product Certifications:
- CCC || CSA || GL || RCM || CE || EAC || UL
- Creepage Distance:
- 4 kV/3 IEC 60664-1
- Pollution Degree:
- 3 IEC 60664-1
- Insulation Resistance:
- 100 MOhm 500 V DC IEC 60664-1
- Voltage Range:
- 0.85...1.1 Us
- Discrete Output Type:
- relay
- Product Or Component Type:
- single function relay
- Mechanical Durability:
- 10000000 cycles
- China Rohs Regulation:
- X
- Reset Time:
- 100 ms on de-energisation
- Sustainable Offer Status:
- Green Premium product
- Range Of Product:
- Harmony Timer Relays
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- Temperature Drift:
- +/- 0.05 %/°C
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Rohs Exemption Information:
- Yes
- Vibration Resistance:
- 20 m/s² 10-150 Hz)IEC 60068-2-6
- Connections - Terminals:
- screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end |
- Environmental Disclosure:
- ENVPEP1401008EN
- Power Consumption In W:
- 2 W 240 V DC
- Control Type:
- rotary knob
- Safety Reliability Data:
- MTTFd = 194 years || B10d = 180000
- Maximum Switching Voltage:
- 250 V AC
- Repeat Accuracy:
- +/- 0.5 % IEC 61812-1
- Mounting Position:
- any position
- Power Consumption In Va:
- 3-3 VA 240 V AC
- Net Weight:
- 0.1 kg
- Maximum Delay Response:
- 350 ms
- Overvoltage Category:
- III IEC 60664-1
- Time Delay Type:
- delay on de-energization
- Width:
- 22.5 mm
- Electromagnetic Compatibility:
- fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 || surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 || surge immunity test - test level: 2
- Time Delay Range:
- 10...100 s || 1...10 min || 1...10 s || 0.3...3 s || 3...30 s || 0.05...1 s || 30...300 s
- Ip Degree Of Protection:
- housing IP40 IEC 60529 || front face IP50 IEC 60529 || terminals IP20 IEC 60529
- Mounting Support:
- 35 mm DIN rail conforming to IEC 60715
- Device Short Name:
- RE22
- Mercury Free:
- Yes
- Contacts Type And Composition:
- 1 C/O timed contact, cadmium free
- [Uimp] Rated Impulse Withstand Voltage:
- 5 kV 1.2-50 µs IEC 60664-1
- Catalog:
- View
- Datasheet:
- View