Schneider Electric

Schneider Electric RE22R2ACMR On Delay Timer

(No reviews yet) Write a Review
SKU:
RE22R2ACMR
UPC:
3606480792519
Condition:
New
Width:
22.5 mm
Standards:
UL 508 || IEC 61812-1
Mercury Free:
Yes
Dielectric Strength:
2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
Time Delay Range:
3...30 h || 30...300 h || 0.05...1 s || 30...300 s || 0.3...3 s || 10...100 s || 1...10 s || 3...30 min || 30...300 min || 3...30 s
Minimum Pulse Duration:
100 ms with load in parallel || 30 ms
Nominal Output Current:
0.333333333333333
Safety Reliability Data:
MTTFd = 251.1 years || B10d = 230000
Net Weight:
0.105 kg
Insulation Resistance:
100 MOhm 500 V DC IEC 60664-1
Minimum Switching Current:
10 mA 5 V DC
Electromagnetic Compatibility:
fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 || surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 || surge immunity test - test level: 2
Voltage Drift:
+/- 0.2 %/V
Shock Resistance:
15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Contacts Type And Composition:
1 C/O timed contact, cadmium free || 1 C/O timed or instantaneous contact, cadmium free
Ambient Air Temperature For Operation:
-20-60 °C
Tightening Torque:
0.6-1 N.m IEC 60947-1
Directives:
2004/108/EC - electromagnetic compatibility || 2006/95/EC - low voltage directive
Voltage Range:
0.85...1.1 Us
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Housing Material:
self-extinguishing
Setting Accuracy Of Time Delay:
+/- 10 % of full scale 25 °C IEC 61812-1
Ip Degree Of Protection:
housing IP40 IEC 60529 || front face IP50 IEC 60529 || terminals IP20 IEC 60529
Discrete Output Type:
relay
Creepage Distance:
4 kV/3 IEC 60664-1
Repeat Accuracy:
+/- 0.5 % IEC 61812-1
China Rohs Regulation:
X
Vibration Resistance:
20 m/s² 10-150 Hz)IEC 60068-2-6
Time Delay Type:
on-delay and off-delay
Status Led:
Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised
Temperature Drift:
+/- 0.05 %/°C
Pollution Degree:
3 IEC 60664-1
Environmental Disclosure:
ENVPEP1401008EN
Power Consumption In Va:
3-3 VA 240 V AC
Range Of Product:
Harmony Timer Relays
Connections - Terminals:
screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end |
Mounting Support:
35 mm DIN rail conforming to IEC 60715
Control Type:
rotary knob || diagnostic button
Rohs Exemption Information:
Yes
Input Voltage:
<= 2.4 V
Maximum Switching Current:
0.333333333333333
[Uimp] Rated Impulse Withstand Voltage:
5 kV 1.2-50 µs IEC 60664-1
Power Consumption In W:
1.5 W 240 V DC
Product Or Component Type:
single function relay
Ambient Air Temperature For Storage:
-40-70 °C
Mounting Position:
any position
Overvoltage Category:
III IEC 60664-1
Immunity To Microbreaks:
10 ms
Mechanical Durability:
10000000 cycles
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Certifications:
RCM || CCC || CSA || UL || EAC || CE || GL
Relative Humidity:
95-95 % 25-55 °C
Maximum Switching Voltage:
250 V AC
Sustainable Offer Status:
Green Premium product
Switching Capacity In Va:
2000 VA
[Us] Rated Supply Voltage:
24...240 V AC/DC 50/60 Hz
Electrical Durability:
100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1
Maximum Delay Response:
100 ms
Circularity Profile:
ENVEOLI1401008EN
Device Short Name:
RE22
Supply Frequency:
50...60 Hz +/- 5 %
Reset Time:
120 ms on de-energisation
Catalog:
View
Datasheet:
View
$72.10

Description

This Harmony RE22 modular dual function timer can be set between 0.05 seconds and 300 hours. It provides function A and function Aw and it is mountable on DIN rail. This modular single function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Selectable timing range offers a one stop solution for your power management system. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
View AllClose