Schneider Electric RE48ACV12MW Flashing Timer 2C/O 48Mm

(No reviews yet) Write a Review
SKU:
RE48ACV12MW
UPC:
3389110649741
Condition:
New
Discrete Output Type:
relay
Product Front Plate Size:
48 x 48 mm
Time Delay Type:
asymmetrical flashing
Standards:
EN 50081-1/2 || EN 50082-1/2 || IEC 61812-1 || 93/68/EEC || 89/336/EEC || IEC 60669-2-3 || 73/23/EEC
Sustainable Offer Status:
Green Premium product
Voltage Range:
0.85...1.1 Us AC || 0.9...1.1 Us DC
Resistance To Electrostatic Discharge:
6 kV in contact IEC 61000-4-2 level 3 || 8 kV in air IEC 61000-4-2 level 3
Circularity Profile:
ENVEOLI1512002EN
Immunity To Radioelectric Fields:
10 V 0.15...80 MHz)IEC 61000-4-6 level 3
Surge Withstand:
1 kV differential mode IEC 61000-4-5 level 3 || 2 kV common mode IEC 61000-4-5 level 3
Dielectric Strength:
1 kV 1 mA/1 minute IEC 61812-1
Electrical Connection:
plug-in sub-base 11
Humidity Drift:
+/- 0.05 %/%RH of the maximum setting value IEC 61812-1
Time Delay Range:
0.2...12 min || 5...300 s || 0.02...1.2 s || 0.5...30 min || 5...300 h || 0.2...12 h || 0.2...12 s || 0.5...30 s || 2...120 s || 0.05...3 s || 2...120 min || 5...300 min || 0.5...30 h || 2...120 h
Minimum Pulse Duration:
20 ms
Relative Humidity:
93-93 % without condensation IEC 60068-2-3
Resistance To Electromagnetic Fields:
10 V/m 26 MHz to 1 GHz IEC 61000-4-3 level 3
Immunity To Voltage Dips:
30 % / 10 ms IEC 61000-4-11 || 60 % / 100 ms IEC 61000-4-11 || 95 % / 5 s IEC 61000-4-11
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Temperature For Storage:
-40-70 °C
Repeat Accuracy:
+/- 0.2 % of the maximum setting value IEC 61812-1
Disturbance Radiated/Conducted:
class B 0.15...30 MHz EN 55022 (EN 55011 group 1)
Breaking Capacity:
1250 VA
Power Consumption In Va:
1.1 VA 24 V || 4.8 VA 240 V
Control Type:
selector switch front panel
Vibration Resistance:
0.35 mm 10-55 Hz)IEC 60068-2-6
Housing Material:
self-extinguishing
Maximum Switching Voltage:
250 V AC/DC
Marking:
CE
Minimum Switching Current:
100 mA
Immunity To Microbreaks:
10 ms
Ambient Air Temperature For Operation:
-20-50 °C
Power Consumption In W:
0.5 W 24 V || 1.7 W 240 V
Resistance To Fast Transients:
2 kV IEC 61000-4-4 level 4 capacitive connecting clip) || 4 kV IEC 61000-4-4 level 4 direct)
Maximum Switching Current:
0.208333333333333
Setting Accuracy Of Time Delay:
+/- 5 % of full scale 25 °C IEC 61812-1
Temperature Drift:
+/- 0.02 %/°C of the maximum setting value IEC 61812-1
Pick Up Duration:
55 ms
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Product Or Component Type:
dual function relay
Line Rated Current:
0.208333333333333
China Rohs Regulation:
X
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
On-Load Factor:
1
Local Signalling:
for output relay state 1 LED (yellow) || for flashing: relay energised timing in progress LED indicator (green) || for on steady: relay energised, no timing in progress LED indicator (green)
Protection Against Electric Shocks:
4 kV class III IEC 60664-1 || 4 kV class III IEC 61812-1
Electrical Durability:
100000 cycles
[Us] Rated Supply Voltage:
24...240 V AC/DC 50/60 Hz
Environmental Disclosure:
ENVPEP1512002EN
Rohs Exemption Information:
Yes
Voltage Drift:
+/- 0.2 %/V of the maximum setting value 48...240 V || +/- 1 %/V of the maximum setting value 24...48 V
Component Name:
RE48A
Warranty:
18 months
Product Certifications:
UL || C-tick || cULus || CSA
Mounting Support:
base mounted: socket || panel mounted: system supplied with the product
Ip Degree Of Protection:
IP40 IEC 60529 housing) || IP50 IEC 60529 front face)
Mercury Free:
Yes
Reset Time:
25 ms on de-energisation
Range Of Product:
Harmony Timer Relays
Output Voltage:
240 V 5 A AC-12 || 30 V 2 A DC-13 || 240 V 1.5 A AC-15
Net Weight:
0.14 kg
Contacts Type And Composition:
2 C/O timed contacts, AgNi (cadmium free)
Mechanical Durability:
30000000 cycles
California Proposition 65:
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other repr
$88.00

Description

This Harmony RE48 timing relay can be set between 0.2 seconds and 300 hours, has an output rating of 5A, is 22.5mm wide and can be supplied with 24V to 240V AC. It is a plug-in device, meaning it is quick and easy to install with the need for tools. It also offers a sealable cover, simple and precise settings with rotary trimmers. This relay offers L, Li flashing functions. It is designed for both panel mooting or socket plug in, this gives more flexibility in designing installations and stocking spares. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. Status display with 2 LEDs, visually inspect the status of you system without specialized tools. 0 0 0 0 0 0 0 0 0 0 0 0
View AllClose