Schneider Electric RGF36120U31A Molded Case Circuit Breaker 600V 1200A

(No reviews yet) Write a Review
SKU:
RGF36120U31A
UPC:
785901443919
Condition:
New
Eu Rohs Directive:
Compliant
Product Name:
PowerPact R
Mercury Free:
Yes
Ambient Air Temperature For Storage:
-50-85 °C
Local Signalling:
alarm 1 LED yellow)long-time pick up)
Pvc Free:
Yes
Product Or Component Type:
circuit breaker
Height:
16.24 in
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Utilisation Category:
category A
Awg Gauge:
AWG 3/0...750 kcmil aluminium/copper
Circularity Profile:
ENVEOLI1407013EN
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Line Rated Current:
1200-1200 A
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Halogen Content Performance:
Halogen free plastic parts product
Circuit Breaker Application:
HACR rated
Suitability For Isolation:
yes IEC 60947-2
Device Application:
distribution
Trip Unit Name:
MicroLogic 3.0
Standards:
UL || CSA || NEMA || NMX J-266 || IEC 60947-2
Ip Degree Of Protection:
IP40
Mounting Mode:
unit mount busbar)
Rohs Exemption Information:
Yes
Quality Labels:
CE
Pollution Degree:
3 IEC 60947-1
Breaking Capacity Code:
G
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Poles Description:
3P
Tightening Torque:
68-68 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 68-68 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
Electrical Connection:
busbar connection, line || busbar connection, load
Mounting Support:
busbar
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Environmental Disclosure:
ENVPEP1407013EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Terminal Identifier:
AL2500RK
Width:
16.53 in
Network Frequency:
50/60 Hz
Control Type:
operating handle
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Certifications:
UL || CSA || NOM
Net Weight:
52 lb(US)
Wire Stripping Length:
35 mm
Ambient Air Temperature For Operation:
-25-70 °C
Depth:
14.49 in
Range:
PowerPact
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Sustainable Offer Status:
Green Premium product
Warranty:
18 months
Continuous Current Rating:
0.8
Quantity Per Set:
1
Brochure:
View
Catalog:
View
Datasheet:
View
$34,740.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. The circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose