- Product Name:
- PowerPact R
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Ambient Air Temperature For Operation:
- -25-70 °C
- Eu Rohs Directive:
- Compliant with Exemptions
- Circularity Profile:
- ENVEOLI2206034EN
- Mounting Support:
- busbar
- Terminal Identifier:
- AL2500RK
- Device Application:
- distribution
- Poles Description:
- 3P
- Rohs Exemption Information:
- Yes
- Pollution Degree:
- 3 IEC 60947-1
- Quantity Per Set:
- 1
- Line Rated Current:
- 2500-2500 A
- Mercury Free:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Width:
- 16.53 in
- Continuous Current Rating:
- 0.8
- Breaking Capacity Code:
- K
- [Ics] Rated Service Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz IEC 60947-2 || 55 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Product Certifications:
- UL || CSA || NOM
- Environmental Disclosure:
- ENVPEP2206034EN
- Tightening Torque:
- 68-68 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 68-68 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
- Depth:
- 14.49 in
- Wire Stripping Length:
- 35 mm
- Standards:
- UL || CSA || NEMA || NMX J-266 || IEC 60947-2
- Sustainable Offer Status:
- Green Premium product
- Suitability For Isolation:
- yes IEC 60947-2
- Network Frequency:
- 50/60 Hz
- Halogen Content Performance:
- Halogen free plastic parts product
- Warranty:
- 18 months
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Quality Labels:
- CE
- Product Or Component Type:
- circuit breaker
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 65 kA 600 V AC 50/60 Hz UL 489 || Icu 85 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 70 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Control Type:
- operating handle
- Ip Degree Of Protection:
- IP40
- Electrical Connection:
- busbar connection, line || busbar connection, load
- Pvc Free:
- Yes
- Utilisation Category:
- category A
- Mounting Mode:
- unit mount busbar)
- Awg Gauge:
- AWG 3/0...750 kcmil aluminium/copper
- Net Weight:
- 52 lb(US)
- Range:
- PowerPact
- Ambient Air Temperature For Storage:
- -50-85 °C
- Height:
- 16.24 in
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 6.0 A, LSIG
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Local Signalling:
- alarm 1 LED yellow)long-time pick up) || 1 LED red)long-time pick up) || trip causes 1 LED red) || 1 LED red)digital ammeter) || ground indicator 1 LED red) || phase-loading LED green)load balancing)
- Trip Unit Name:
- MicroLogic 6.0 A
- Circuit Breaker Application:
- HACR rated
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.