This Harmony RM17-UB relay allows monitoring of voltage control in single phase networks. This modular multi function single phase voltage control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
- Range Of Product:
- Harmony Control Relays
- Quality Labels:
- CE
- Measurement Accuracy:
- +/- 10 % of the full scale value
- Output Contacts:
- 1 C/O
- Operating Position:
- any position without derating
- Power Consumption In Va:
- 0-3.9 VA AC
- Electrical Durability:
- 100000 cycles
- Circularity Profile:
- ENVEOLI1504008EN
- Directives:
- 73/23/EEC - low voltage directive || 89/336/EEC - electromagnetic compatibility
- Product Certifications:
- C-tick || GOST || GL || CSA || UL
- Pollution Degree:
- 3 IEC 60664-1
- Repeat Accuracy:
- +/- 0.5 % input and measurement circuit || +/- 1 % time delay
- Mechanical Durability:
- 30000000 cycles
- Rohs Exemption Information:
- Yes
- Safety Reliability Data:
- MTTFd = 502.2 years || B10d = 470000
- Compatibility Code:
- RM17
- Insulation Resistance:
- > 500 MOhm 500 V DC IEC 60255-5 || > 500 MOhm 500 V DC IEC 60664-1
- Maximum Measuring Cycle:
- 150 ms measurement cycle as true rms value
- Electromagnetic Compatibility:
- emission standard for industrial environments conforming to IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 || immunity for industrial environments conforming to NF EN/IEC 6
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Immunity To Microbreaks:
- 20 ms
- Utilisation Category:
- AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
- Environmental Disclosure:
- ENVPEP1504008EN
- Switching Capacity In Va:
- 1250 VA
- Maximum Power Consumption In W:
- 1.6 W DC
- Mounting Support:
- 35 mm symmetrical DIN rail conforming to IEC 60715
- Vibration Resistance:
- 0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
- Run-Up Delay At Power-Up:
- 1000 ms DC || 500 ms AC
- Time Delay Type:
- adjustable 0.1...10 s, 0 + 10 % Tt- time delay upon fault
- Relay Monitored Parameters:
- self-powered || overvoltage and undervoltage detection
- Functionality:
- overvoltage and undervoltage detection
- Net Weight:
- 0.08 kg
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Us] Rated Supply Voltage:
- self-powered
- Control Type:
- without test button
- Standards:
- IEC 60255-6
- Nominal Output Current:
- 0.208333333333333
- Shock Resistance:
- 5 gn IEC 60068-2-27
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- [Ui] Rated Insulation Voltage:
- 250 V IEC 60664-1 || 400 V IEC 60664-1
- Hysteresis:
- 3-3 % fixed threshold setting
- Maximum Switching Voltage:
- 250 V AC/DC
- Ambient Air Temperature For Operation:
- -20-50 °C
- Maximum Switching Current:
- 5 A AC/DC
- Ambient Air Temperature For Storage:
- -40-70 °C
- China Rohs Regulation:
- X
- Measurement Error:
- < 1 % over the whole range with voltage variation || 0.2 %/°C with temperature variation
- Contacts Type And Composition:
- 1 C/O
- Relative Humidity:
- 95-95 % 55-55 °C IEC 60068-2-30
- Measurement Range:
- 20...80 V voltage AC/DC 50/60 Hz
- Polarity:
- non reversible polarity on DC supply
- Sustainable Offer Status:
- Green Premium product
- Connections - Terminals:
- screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end ||
- Ip Degree Of Protection:
- IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
- Product Specific Application:
- for single-phase and DC supply
- Minimum Switching Current:
- 10 mA 5 V DC
- Overvoltage Category:
- III IEC 60664-1
- Operating Rate:
- <= 360 operations/hour full load
- Non-Dissipating Shock Wave:
- 4 kV IEC 60255-5 || 4 kV IEC 60664-1 || 4 kV IEC 61000-4-5
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Width:
- 17.5 mm
- Control Circuit Frequency:
- 50...60 Hz +/- 10 %
- Mercury Free:
- Yes
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- Reset Time:
- 1500 ms time delay
- Relay Name:
- RM17UBE
- Relay Type:
- voltage control relay
- Supply Voltage Limits:
- 15-100 V AC/DC
- Housing Material:
- self-extinguishing plastic
- Dielectric Test Voltage:
- 2 kV AC 50 Hz, 1 min IEC 60255-5 || 2 kV AC 50 Hz, 1 min IEC 60664-1
- Warranty:
- 18 months
- Local Signalling:
- for power ON LED (green) || for relay ON LED (yellow)
- Product Or Component Type:
- voltage control relay
- Catalog:
- View
- Datasheet:
- View