- Response Time:
- > 50 ms (input Y1 (contact Y1-T1) and push-button)
- Maximum Switching Current:
- 5 A AC || 5 A DC
- Product Or Component Type:
- motor temperature control relay
- Vibration Resistance:
- 0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
- Range Of Product:
- Harmony Control Relays
- Environmental Disclosure:
- ENVPEP1504008EN
- Local Signalling:
- for power ON LED (green) || for phase of relay (R2) LED (yellow) || for temperature of relay (R1) LED (yellow)
- Resistance Across Terminals:
- 602 mOhm
- Utilisation Category:
- AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1
- Power Consumption In Va:
- 0-4 VA 24...240 V AC
- Reset Threshold:
- 1650 Ohm +/- 10 % temperature control circuit
- Contacts Type And Composition:
- 2 NO
- Tripping Threshold:
- 3100 Ohm +/- 10 % temperature control circuit
- Overvoltage Category:
- III IEC 60664-1
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Ambient Air Temperature For Operation:
- -20-50 °C
- [Us] Rated Supply Voltage:
- AC/DC non self-powered
- Net Weight:
- 0.13 kg
- Maximum Resistance:
- 1500 Ohm temperature sensor 20 °C
- Measurement Voltage Limits:
- 176-528 V AC
- Product Specific Application:
- for 3-phase supply
- China Rohs Regulation:
- X
- Shock Resistance:
- 15 gn 11 ms IEC 60255-21-1
- Ip Degree Of Protection:
- IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
- Connections - Terminals:
- screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end ||
- [Uc] Control Circuit Voltage:
- <= 3.6 V temperature control circuit T1-T2 terminals open)
- Run-Up Delay At Power-Up:
- 500 ms
- Immunity To Microbreaks:
- 20 ms 20.4 V
- Directives:
- 73/23/EEC - low voltage directive || 89/336/EEC - electromagnetic compatibility
- Electrical Durability:
- 10000 cycles
- Product Certifications:
- CSA || C-tick || GOST || UL || GL
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Uc] Control Circuit Voltage:
- 24...240 V
- Circularity Profile:
- ENVEOLI1504008EN
- Supply Voltage Limits:
- 20.4-264 V AC || 20.4-264 V DC
- Non-Dissipating Shock Wave:
- 4 kV
- Supply Frequency:
- 50/60 Hz +/- 10 %
- Nominal Output Current:
- 0.208333333333333
- Housing Material:
- self-extinguishing plastic
- Time Delay Type:
- without
- Mechanical Durability:
- 30000000 cycles
- Minimum Switching Current:
- 10 mA 5 V DC
- Relative Humidity:
- 95-95 % 55-55 °C IEC 60068-2-30
- Width:
- 35 mm
- Warranty:
- 18 months
- Dielectric Test Voltage:
- 2 kV AC 50 Hz, 1 min
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Output Contacts:
- 2 NO
- Sustainable Offer Status:
- Green Premium product
- Relay Monitored Parameters:
- phase failure detection || phase sequence || test/reset button || motor temperature via PTC probe || selection (with or without memory)
- Operating Rate:
- <= 360 operations/hour full load
- Operating Position:
- any position without derating
- Standards:
- IEC 60255-6 || IEC 60034-11-2
- Maximum Switching Voltage:
- 250 V AC || 250 V DC
- Measurement Range:
- 208...480 V voltage AC || 0...20 Ohm short-circuit detection
- [Ui] Rated Insulation Voltage:
- 400 V IEC 60664-1
- Relay Name:
- RM35TM
- Rohs Exemption Information:
- Yes
- Mounting Support:
- 35 mm symmetrical DIN rail conforming to IEC 60715
- Maximum Power Consumption In W:
- 0.5 W DC
- Short-Circuit Current:
- 0.007 A temperature sensing circuit T1-T2 terminals short circuited)
- Switching Capacity In Va:
- 1250 VA
- Voltage Range:
- 176...528 V
- Reset Time:
- 10000 ms output
- Electromagnetic Compatibility:
- emission standard for industrial environments conforming to IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 || immunity for industrial environments conforming to IEC 61000-6
- Marking:
- CE
- Relay Type:
- motor temperature control relay
- Control Circuit Frequency:
- 50...60 Hz +/- 10 %
- Pollution Degree:
- 3 IEC 60664-1
- Control Type:
- with test button
- Insulation Resistance:
- > 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || > 500 MOhm 500 V DC between supply and relay ou
- Ambient Air Temperature For Storage:
- -40-70 °C
- Mercury Free:
- Yes
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- QN-QUOTE-REQUEST: