Control Circuit Voltage Limits:
15 % + 10 % Un
Overvoltage Category:
III IEC 60664-1
Standards:
IEC 60255-6
Net Weight:
0.08 kg
Quality Labels:
CE
Hysteresis:
5-50 % threshold setting
Shock Resistance:
5 gn IEC 60068-2-27
Compatibility Code:
RM3
Maximum Switching Current:
5 A AC/DC
Maximum Power Consumption In W:
0.6 W DC
Relay Name:
RM35UA
Ambient Air Temperature For Storage:
-40-70 °C
Ip Degree Of Protection:
IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
Non-Dissipating Shock Wave:
4 kV IEC 60255-5 || 4 kV IEC 60664-1 || 4 kV IEC 61000-4-5
Utilisation Category:
AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
Supply Voltage Limits:
20.4-264 V AC/DC
Maximum Measuring Cycle:
30 ms measurement cycle as true rms value
Time Delay Type:
adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault
Power Consumption In Va:
0-3.5 VA AC
Reset Time:
1500 ms time delay
Range Of Product:
Harmony Control Relays
Pollution Degree:
3 IEC 60664-1
Tightening Torque:
0.6-1 N.m IEC 60947-1
Contacts Type And Composition:
2 C/O
Maximum Switching Voltage:
250 V AC/DC
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Safety Reliability Data:
B10d = 290000 || MTTFd = 308.2 years
Mechanical Durability:
30000000 cycles
Operating Rate:
<= 360 operations/hour full load
Control Circuit Frequency:
40...70 Hz +/- 10 %
Output Contacts:
2 C/O
Nominal Output Current:
0.208333333333333
Dielectric Test Voltage:
2 kV AC 50 Hz, 1 min IEC 60255-5 || 2 kV AC 50 Hz, 1 min IEC 60664-1
Sensitivity Scale:
0.05...0.5 V E1-M terminals || 0.3...3 V E2-M terminals || 0.5...5 V E3-M terminals
Mounting Support:
35 mm symmetrical DIN rail conforming to IEC 60715
Electromagnetic Compatibility:
emission standard for industrial environments conforming to IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 || immunity for industrial environments conforming to NF EN/IEC 6
Circularity Profile:
ENVEOLI1504008EN
Immunity To Microbreaks:
10 ms
Vibration Resistance:
0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
Electrical Durability:
100000 cycles
Measurement Error:
+/- 0.05 %/°C with temperature variation || < 1 % over the whole range with voltage variation
Threshold Setting:
10...100 %
Minimum Switching Current:
10 mA 5 V DC
Mercury Free:
Yes
Insulation Resistance:
> 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || > 500 MOhm 500 V DC between supply and relay ou
China Rohs Regulation:
X
Resistance Across Terminals:
30 mOhm E2-M terminals || 5 mOhm E1-M terminals || 50 mOhm E3-M terminals
Polarity:
non reversible polarity on DC supply
Repeat Accuracy:
+/- 0.5 % input and measurement circuit || +/- 2 % time delay
Product Or Component Type:
voltage control relay
Operating Position:
any position without derating
Ambient Air Temperature For Operation:
-20-50 °C
[Ui] Rated Insulation Voltage:
250 V IEC 60664-1 || 600 V IEC 60664-1
Relay Type:
multifunction voltage control relay
Relative Humidity:
95-95 % 55-55 °C IEC 60068-2-30
Directives:
73/23/EEC - low voltage directive || 89/336/EEC - electromagnetic compatibility
Switching Capacity In Va:
1250 VA
Measurement Accuracy:
+/- 10 % of the full scale value
Environmental Disclosure:
ENVPEP1504008EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
35 mm
Sustainable Offer Status:
Green Premium product
Housing Material:
self-extinguishing plastic
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Rohs Exemption Information:
Yes
Product Certifications:
GOST || CSA || GL || UL || C-tick
Connections - Terminals:
screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end || scr
Run-Up Delay At Power-Up:
600 ms
[Us] Rated Supply Voltage:
AC/DC non self-powered
Local Signalling:
for power ON LED (green) || for relay ON LED (yellow)
Relay Monitored Parameters:
overvoltage or undervoltage detection
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Warranty:
18 months
Control Type:
without test button
Measurement Range:
0.05...5 V voltage AC/DC
  • Schneider Electric RM35UA11MW Ov Or Uv Relay 0 05..5V 24-240Vac/Dc 2Co
  • Schneider Electric RM35UA11MW Ov Or Uv Relay 0 05..5V 24-240Vac/Dc 2Co
  • Schneider Electric RM35UA11MW Ov Or Uv Relay 0 05..5V 24-240Vac/Dc 2Co
$157.00

Description

This Harmony RM35-U multi function control relay allows monitoring of voltage control. This modular multi function control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0