- Software Designation:
- Zelio NFC downloadable from Google Play store)
- Net Weight:
- 0.125 kg
- Rohs Exemption Information:
- Yes
- Maximum Operating Frequency:
- 13.56 MHz
- Hysteresis:
- 3-3 % fixed phase failure detection
- Contacts Material:
- cadmium free
- Environmental Disclosure:
- ENVPEP1504008EN
- [Ith] Conventional Free Air Thermal Current:
- 0.333333333333333
- Product Compatibility:
- NFC enabled mobile device
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other repr
- On-Load Factor:
- 1
- Ambient Air Temperature For Storage:
- -40-70 °C
- Maximum Measuring Cycle:
- 150 ms measurement cycle as true rms value
- [Us] Rated Supply Voltage:
- AC non self-powered
- Mechanical Durability:
- 10000000 cycles
- Depth:
- 99 mm
- Ambient Air Temperature For Operation:
- -20-60 °C
- Shock Resistance:
- 15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27
- Response Time:
- <= 300 ms
- Product Certifications:
- CE || UL || CSA || CCC || EAC || RCM
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Switching Capacity In Va:
- 2000 VA
- Overvoltage Category:
- III IEC 60664-1 || III UL 508
- Sustainable Offer Status:
- Green Premium product
- Mounting Support:
- 35 mm DIN rail conforming to IEC 60715
- Pollution Degree:
- 3 IEC 60664-1 || 3 UL 508
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Repeat Accuracy:
- +/- 0.5 % input circuit || +/- 3 % time delay
- Control Type:
- without test button
- Utilisation Category:
- AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1
- Dielectric Test Voltage:
- 2.5 kV AC 50 Hz, 1 min IEC 60255-27
- Circularity Profile:
- ENVEOLI1504008EN
- Run-Up Delay At Power-Up:
- 650 ms
- Relative Humidity:
- 93-97 % 25-55 °C IEC 60068-2-30
- Connections - Terminals:
- screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.5...2 x 1.5 mm² AWG 20...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end |
- Supply Voltage Limits:
- 166.4-576 V AC line to line || 96-332.4 V AC line to neutral
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Mercury Free:
- Yes
- Ip Degree Of Protection:
- IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP40 IEC 60529 front panel)
- Measurement Error:
- < 0.05 %/Hz with frequency variation || < 0.05 %/°C with temperature variation
- Electrical Durability:
- 100000 cycles
- Width:
- 22.5 mm
- Height:
- 90 mm
- Immunity To Microbreaks:
- 10 ms
- Standards:
- IEC 60255-1
- Product Or Component Type:
- 3-phase control relay
- Local Signalling:
- Un, green LED steady)power ON || R1, amber LED steady)relay energised || R1, amber LED blinking)timing in progress || R2, amber LED steady)relay energised || R2, amber LED blinking)timing in progress || PL, red LED steady)alarm phase failure triggere
- Directives:
- 2014/30/EU - electromagnetic compatibility || 2014/35/EU - low voltage directive || 2014/53/EU - radio equipment directive
- Output Contacts:
- 2 C/O
- [Ui] Rated Insulation Voltage:
- 400 V
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV 1.2/50 µs
- Measurement Range:
- 208...480 V AC
- Time Delay Type:
- on-delay 0.1 s...60 min || off-delay 0.1 s...60 min || adjustable 0.1 s...1 min
- Reset Time:
- 1500 ms at maximum voltage
- Contacts Type And Composition:
- 2 C/O
- Electromagnetic Compatibility:
- voltage dips and interruptions immunity test - test level: 70 % (25/30 cycles) conforming to IEC 61000-4-11 || electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 || radiated radio-frequency electromagne
- Vibration Resistance:
- 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 58.1-150 Hz) not in operation IEC 60068-2-6 || 0.035 mm 10-58.1 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
- Housing Material:
- self-extinguishing plastic
- Setting Accuracy Of Time Delay:
- +/- 3 % 10 s...60 min || +/- 300 ms 0...10 s
- Phase:
- 3 phase
- Mounting Position:
- any position
- Maximum Switching Voltage:
- 250 V AC
- Nominal Power:
- 0.0002 mW
- Insulation Resistance:
- > 100 MOhm 500 V DC IEC 60255-27
- Threshold Adjustment Voltage:
- 2...20 % of Un selected
- Relay Type:
- control relay
- China Rohs Regulation:
- X
- Relay Monitored Parameters:
- phase sequence || phase failure detection || overvoltage detection || undervoltage detection || overfrequency and underfrequency || asymmetry
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1 || 5.3-8.8 lbf.in IEC 60947-1
- Operating System:
- Android
- Alarm Threshold:
- 166...576 V adjustable overvoltage and undervoltage detection (line to line) || 96...332 V adjustable overvoltage and undervoltage detection (line to neutral) || 5...150 V adjustable asymmetry || 45...66 Hz adjustable overfrequency or underfrequency
- Software Version:
- V4.4 and above
- Setting Accuracy Of The Switching Threshold:
- +/- (1.5 % + 1 V)
- Minimum Switching Current:
- 100 mA 6 V
- Supply Frequency:
- 50...60 Hz +/- 10 %
- Relay Name:
- RMNF22
- Range Of Product:
- Harmony Control Relays
- Maximum Switching Current:
- 8 A AC
- Power Consumption In Va:
- 4-4 VA 480 V AC 60 Hz