Schneider Electric TM262M25MESS8T Motion Ctrl M262 3Ns/Inst 8 Ax. Eth. S3

(No reviews yet) Write a Review
SKU:
TM262M25MESS8T
UPC:
3606489604219
Condition:
New
Positioning Functions:
libraries axes coordinated || libraries axes synchronous || Sercos 3 motion bus
Discrete Input Voltage Type:
DC
Discrete Output Type:
transistor
Product Certifications:
CE || cULus || cULus HazLoc Class I Division 2 CSA 22-2 No 213 || RCM || EAC || Achilles || KC
Power Consumption In W:
82 W
Discrete Output Number:
4 transistor fast output
Communication Service:
MQTTs || OPC UA server (Encrypt) || OPC UA client (Encrypt) || HTTPs Methods (API) || web server || web visu || TLS 1.2 || TLS 1.3 || SNTP || NTP client/server || FTP client/server || FTPs server || SQL client (remote access) || DHCP client || DHCP s
Shock Resistance:
15 gn 11 ms
Maximum Number Of I/O Expansion Module:
7 TM3 IO module (remote I/O-Architecture) || 7 TM3 IO module (local I/O-Architecture) || 64 TM3, TM5 or TM7 IO island (distributed I/O-Architecture)
China Rohs Regulation:
X
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Overvoltage Protection:
with
Electrical Connection:
removable spring terminal block for inputs and outputs || removable spring terminal block for connecting the 24 V DC power supply
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Discrete Output Logic:
source
Rohs Exemption Information:
Yes
Input Impedance:
2.81 kOhm input
Ambient Air Temperature For Storage:
-40-85 °C
Response Time:
<= 1 µs turn-on, I0...I3 fast input || <= 1 µs turn-off, I0...I3 fast input || <= 1 µs turn-on, Q0...Q3 fast output || <= 1 µs turn-off, Q0...Q3 fast output
Application Structure:
8 event tasks || 4 cyclic master tasks || 3 cyclic master tasks + 1 freewheeling task || 8 external event tasks
[Us] Rated Supply Voltage:
24 V DC - 15...20 %
Accuracy:
+/- 0.1 % 0.02-0.1 kHz fast output || +/- 1 % 0.1-1 kHz fast output
Backup Time:
1000 h 25 °C
Discrete Input Current:
7.5 mA fast input
Surge Withstand:
1 kV power lines (DC) common mode IEC 61000-4-5 || 1 kV shielded cable common mode IEC 61000-4-5 || 0.5 kV relay output differential mode IEC 61000-4-5 || 1 kV input common mode IEC 61000-4-5 || 1 kV transistor output common mode IEC 61000-4-5
Ambient Air Temperature For Operation:
-20-60 °C horizontal installation) || -20-50 °C vertical installation) || -20-45 °C flat mounting)
Insulation:
between fast input and internal logic 550 V AC || non-insulated between inputs || between output and internal logic 550 V AC || non-insulated between outputs || between input and output 550 V AC || between supply and internal logic 550 V AC || non-in
Discrete Output Voltage:
24 V DC
Immunity To Microbreaks:
0.01 ms
Product Compatibility:
external encoder 5/24 V DC no encoder power supply
Cycle Time:
0.5 ms
Maximum Current Per Output Common:
0.5 A Q0...Q3 fast output
Vibration Resistance:
3.5 mm 2-8.4 Hz symmetrical rail || 1 gn 8.4-200 Hz symmetrical rail || 3.5 mm 2-8.4 Hz panel mounting || 1 gn 8.4-200 Hz panel mounting
Height:
100 mm
Inrush Current:
40 A
Resistance To Conducted Disturbances:
10 V 0.15...80 MHz IEC 61000-4-4 || 3 V 0.1...80 MHz || 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)
Discrete Input Voltage:
24 V
Standards:
UL 61010-1 || UL 61010-2-201 || CSA C22.2 No 61010-1 || CSA C22.2 No 61010-2-201 || CSA C22.2 No 213 || ANSI/ISA 12-12-01 || IEC 61131-2
Maximum Output Frequency:
300 kHz
Clock Drift:
<= 10 s/month 25-25 °C
Range Of Product:
Logic/motion controller - Modicon M262
Reset Time:
200 ms automatic reset fast output
Environmental Disclosure:
ENVPEP1904006EN
Maximum Tungsten Load:
<1.5 W
Electromagnetic Emission:
conducted emissions 120...69 dBµV/m QP power lines)10-150 kHz IEC 55011 || conducted emissions 63 dBμV/m QP power lines)1.5-30 MHz IEC 55011 || radiated emissions 40 dBµV/m30-230 kHz IEC 55011 || conducted emissions 79...63 dBμV/m QP power lines)
Data Storage Equipment:
<= 32 GB SDHC card optional)
Voltage State 0 Guaranteed:
<= 5 V DC
Maximum Leakage Current:
10 µA output
Local Signalling:
for PWR 1 LED (green/red) || for RUN 1 LED (green/red) || for ERROR (fault) 1 LED (green/red) || for stop forced 1 LED (green/red) || for I/O error (I/O) 1 LED (green/red) || for SD card activity 1 LED (green/orange) || for SL activity 1 LED (green/o
Product Or Component Type:
motion controller
Encoder Type:
incremental encoder
Transmission Rate:
115 kbit/s 15-15 m RS485 || 115 kbit/s 3-3 m RS232 || 480 Mbit/s 3-3 m USB || 10/100 Mbit/s Ethernet1 || 10/100/1000 Mbit/s Ethernet2
Output Voltage Limits:
30 V DC
Configurable Filtering Time:
0.001 ms fast input || 0.002 ms fast input || 0.005 ms fast input || 0.01 ms fast input || 0.05 ms fast input || 0.1 ms fast input || 0.5 ms fast input || 1 ms fast input || 4 ms fast input || 12 ms fast input
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Communication Port Protocol:
EtherNet/IP adapter || EtherNet/IP scanner || Modbus TCP client/server || Modbus TCP IO scanner || Modbus TCP NVL || Ethernet RSTP || Modbus SL client/server || Modbus SL IO scanner || Modbus SL modem management || Machine Expert || ASCII manager ||
Discrete Input Logic:
sink
Resistance To Electrostatic Discharge:
4 kV on contact IEC 61000-4-2 || 8 kV on air IEC 61000-4-2
Execution Time For 1 Kinstruction:
0.003 ms
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Memory Capacity:
32 MB program RAM || 32 MB OS/website RAM || 192 MB system memory RAM
Maximum Cable Distance Between Devices:
shielded cable <3 m fast input || shielded cable <3 m fast output || unshielded cable <50 m input || unshielded cable <50 m output || shielded cable <30 m RS485 link || shielded cable <15 m RS232
Operating Altitude:
0...6561.68 ft (0...2000 m)
Protection Type:
short-circuit and overload protection with automatic reset || reverse polarity protection || short-circuit protection
Depth:
90 mm
Net Weight:
0.67 kg
Circularity Profile:
ENVEOLI1904006EN
Maximum Number Of Connected Devices:
EtherNet/IP <64 || Modbus TCP <64 || Modbus TCP/EtherNet/IP <128
Mounting Support:
top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
Data Backed Up:
1 GB built-in flash memory backup of user programs
Voltage State 1 Guaranteed:
>= 15 V DC
Mercury Free:
Yes
Resistance To Electromagnetic Fields:
10 V/m 80 MHz...1 GHz IEC 61000-4-3 || 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3 || 1 V/m 2 GHz...3 GHz IEC 61000-4-3
Pollution Degree:
2
Relative Humidity:
10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
Storage Altitude:
0-3000 m
Pvc Free:
Yes
Integrated Connection Type:
Ethernet/Sercos 1 RJ45 10/100BASE-T || Ethernet 2 2 RJ45 100/1000BASE-T || serial link RJ45 RS232/RS485 || 1 encoder female SUB-D 15 RS422/SSI || Smart Communication Bus || TM3 IO bus || USB type mini B
Discrete Input Number:
4 , discrete input fast input IEC 61131-2 Type 1
Supply Voltage Limits:
20.4-28.8 V DC
Resistance To Fast Transients:
2 kV IEC 61000-4-4 power lines) || 1 kV IEC 61000-4-4 Ethernet line) || 1 kV IEC 61000-4-4 serial link) || 1 kV IEC 61000-4-4 input) || 1 kV IEC 61000-4-4 transistor output)
Width:
125 mm
Discrete I/O Number:
8
Realtime Clock:
with
Upstream Connectivity:
IIoT-ready machine to cloud || connected machine to plant
Ip Degree Of Protection:
IP20
Discrete Output Current:
0.5 A fast output Q0...Q3)
Catalog:
View
Datasheet:
View
  • Schneider Electric TM262M25MESS8T Motion Ctrl M262 3Ns/Inst 8 Ax. Eth. S3
  • Schneider Electric TM262M25MESS8T Motion Ctrl M262 3Ns/Inst 8 Ax. Eth. S3
  • Schneider Electric TM262M25MESS8T Motion Ctrl M262 3Ns/Inst 8 Ax. Eth. S3
$3,831.25

Description

Modicon M262 logic/motion controllers are designed for performance-demanding machines, IIoT-ready and combine logic, motion and safety control applications. TM262M25MESS8T is specialized in the motion control of 4 fast digital inputs and 4 fast digital ouputs, 1 encoder input and up to 8 synchronized axes, embedding a safety control application according to SIL3. This motion controller embeds 3 Ethernet-based networks (EtherNet/IP, Modbus/TCP, Sercos), one serial port (Modbus, ASCII, Machine Expert protocols). Modicon M262 are logic/motion controllers with embedded cloud connectivity, figuring cybersecurity capabilities, supporting monitoring, analytics and predictive maintenance. It is powered with a non-isolated 24V DC power supply, has a built-in overload protection, embeds a dual-core processor, reaches a 5ns/instruction performance. This motion controller has one communication bus (Ethernet, CANopen), one IO bus, one IO port, one encoder connector. It measures 125mm width, 90mm depth, and 100 mm height. It weighs 0.670kg. This controller is designed for machinery requiring integrated IIoT connectivity or encrypted communication. Certified with CE, cULus HazLoc, RCM, EAC, Achilles L2, EU RO Mutual, Conform to UL 61010-1/-2-201, CSAC22.2 No. 61010-1/-2-201, ANSI/ISA 12-12-01, EN 61131-2. This controller is compatible with TMS CANopen/Ethernet smart communication module, Modicon TM3 IO expansion modules, configured by EcoStruxure Machine Expert. Modicon M262 logic controller installs on 35mm DIN rail with Clip-on locks. Modicon M262 logic/motion controllers are the IIoT-ready controllers for performance machines. Modicon M262 logic/motion controllers embed Industrial Internet of Things (IIoT) protocols and encryption to provide direct cloud connectivity & digital services.
View AllClose