Schneider Electric TM3DQ16RG Module Tm3-16 Out Relays Spring
Schneider Electric
$218.75
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The discrete output module provides 16 relay outputs with positive or negative logic. It is an output module with an output voltage of 240V AC, 30V DC and a current consumption of 75mA at 24V DC via bus connector. This product is capable of controlling variable speed drives or any device equipped with a current or voltage input. There is an insulation between output and internal logic at 2300V AC, outputs at 750V AC, output groups at 1500V AC. It is furnished with removable spring terminal for electrical connection with pitch 3.81mm adjustment for outputs. It offers mechanical durability of 20 million cycles. It is an IP20 rated product. Its dimensions are 27.4mm (Width) x 84.6mm (Depth) x 90mm (Height). It weighs 0.130kg. This product is certified by CE, CULus and C-Tick. It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller. It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.
- Relative Humidity:
- 10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
- Electromagnetic Emission:
- radiated emissions 40 dBμV/m QP class A 10 m)30-230 MHz IEC 55011 || radiated emissions 47 dBμV/m QP class A 10 m)230-1000 MHz IEC 55011
- Range Of Product:
- Modicon TM3
- Discrete I/O Number:
- 16
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Resistance To Fast Transients:
- 2 kV relay outputIEC 61000-4-4
- Operating Altitude:
- 0...6561.68 ft (0...2000 m)
- Current Consumption:
- 0 mA 24 V DC via bus connector at state off) || 75 mA 24 V DC via bus connector at state on)
- Height:
- 90 mm
- Electrical Connection:
- 10 x 1.5 mm² removable spring terminal block pitch 3.81 mm for outputs
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Ambient Air Temperature For Storage:
- -25-70 °C
- Width:
- 27.4 mm
- China Rohs Regulation:
- X
- Ip Degree Of Protection:
- IP20 with protective cover in place
- Standards:
- IEC 61131-2
- Minimum Load:
- 10 mA 5 V DC relay output
- Environmental Disclosure:
- ENVPEP1402009EN
- Resistance To Magnetic Fields:
- 30 A/m 50/60 Hz IEC 61000-4-8
- Pollution Degree:
- 2
- Insulation:
- between output and internal logic 2300 V AC || between outputs 750 V AC || between output groups 1500 V AC
- Product Certifications:
- cULus || CE || UKCA || RCM || EAC || cULus HazLoc
- Marking:
- CE
- Ambient Air Temperature For Operation:
- -10-35 °C vertical installation || -10-55 °C horizontal installation
- Vibration Resistance:
- 3.5 mm 5-8.4 Hz DIN rail || 3 gn 8.4-150 Hz DIN rail || 3.5 mm 5-8.4 Hz panel || 3 gn 8.4-150 Hz panel
- Discrete Output Number:
- 16
- Discrete Output Logic:
- positive or negative
- Resistance To Electrostatic Discharge:
- 8 kV in air IEC 61000-4-2 || 4 kV on contact IEC 61000-4-2
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Storage Altitude:
- 0-3000 m
- Mechanical Durability:
- 20000000 cycles
- Rohs Exemption Information:
- Yes
- Circularity Profile:
- ENVEOLI1402009EN
- Discrete Output Type:
- relay normally open
- Depth:
- 84.6 mm
- Discrete Output Current:
- 2000 mA relay output
- Range Compatibility:
- Modicon M241 || Modicon M251 || Modicon M221 || Modicon M262
- Mercury Free:
- Yes
- Product Or Component Type:
- discrete output module
- Resistance To Electromagnetic Fields:
- 10 V/m 80 MHz...1 GHz IEC 61000-4-3 || 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3 || 1 V/m 2 GHz...3 GHz IEC 61000-4-3
- Maximum Cable Distance Between Devices:
- unshielded cable <30 m relay output
- Discrete Output Voltage:
- 240 V AC relay output || 30 V DC relay output
- Local Signalling:
- for output status 1 LED per channel (green)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Shock Resistance:
- 15 gn 11 ms
- Response Time:
- 10 ms (turn-on) || 5 ms (turn-off)
- Mounting Support:
- top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
- Pvc Free:
- Yes
- Reach Free Of Svhc:
- Yes
- Toxic Heavy Metal Free:
- Yes
- Resistance To Conducted Disturbances:
- 10 V 0.15...80 MHz IEC 61000-4-6 || 3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
- Surge Withstand:
- 1 kV I/O common mode IEC 61000-4-5 DC
- Net Weight:
- 0.145 kg
- Sustainable Offer Status:
- Green Premium product
- Catalog:
- View
- Datasheet:
- View