- China Rohs Regulation:
 
                        - X
 
                    
                    
                        
- Control Station Colour:
 
                        - yellow
 
                    
                    
                        
- Product Or Component Type:
 
                        - pendant control station
 
                    
                    
                        
- Net Weight:
 
                        - 1 kg
 
                    
                    
                        
- Reach Regulation:
 
                        - Free of Substances of Very High Concern above the threshold
 
                    
                    
                        
- Vibration Resistance:
 
                        - 15 gn 10-500 Hz)IEC 60068-2-6
 
                    
                    
                        
- Ambient Air Temperature For Operation:
 
                        - -25-70 °C
 
                    
                    
                        
- Vertical Operator Cut-Out Centre:
 
                        - 30 mm
 
                    
                    
                        
- Reach Free Of Svhc:
 
                        - Yes
 
                    
                    
                        
- Environmental Disclosure:
 
                        - ENVPEP070905EN
 
                    
                    
                        
- Product Certifications:
 
                        - UL || CSA || CCC || GOST
 
                    
                    
                        
- Device Short Name:
 
                        - XACA
 
                    
                    
                        
- Standards:
 
                        - CSA C22.2 No 14 || EN/IEC 60947-5-1 || UL 508 || EN/IEC 60204-32
 
                    
                    
                        
- Sustainable Offer Status:
 
                        - Green Premium product
 
                    
                    
                        
- Ambient Air Temperature For Storage:
 
                        - -40-70 °C
 
                    
                    
                        
- Warranty:
 
                        - 18 months
 
                    
                    
                        
- Eu Rohs Directive:
 
                        - Pro-active compliance (Product out of EU RoHS legal scope)
 
                    
                    
                        
- Number Of Cut-Out:
 
                        - 12 cut-outs
 
                    
                    
                        
- Circularity Profile:
 
                        - N/A
 
                    
                    
                        
- Rohs Exemption Information:
 
                        - Yes
 
                    
                    
                        
- Enclosure Material:
 
                        - polypropylene
 
                    
                    
                        
- Cable Entry:
 
                        - rubber sleeve with stepped entry 8-26 mm
 
                    
                    
                        
- California Proposition 65:
 
                        - WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other repr
 
                    
                    
                        
- Electrical Circuit Type:
 
                        - control circuit
 
                    
                    
                        
- Toxic Heavy Metal Free:
 
                        - Yes
 
                    
                    
                        
- Ip Degree Of Protection:
 
                        - IP65 conforming to IEC 60529
 
                    
                    
                        
- Enclosure Type:
 
                        - empty enclosure
 
                    
                    
                        
- Mechanical Durability:
 
                        - 1000000 cycles
 
                    
                    
                        
- Shock Resistance:
 
                        - 100 gn IEC 60068-2-27
 
                    
                    
                        
- Mercury Free:
 
                        - Yes
 
                    
                    
                        
- Control Station Type:
 
                        - double insulated
 
                    
                    
                        
- Overvoltage Category:
 
                        - class II IEC 61140
 
                    
                    
                        
- Ik Degree Of Protection:
 
                        - IK08 EN 50102
 
                    
                    
                        
- Guard Rail:
 
                        - without
 
                    
                    
                        
- Range Of Product:
 
                        - Harmony XAC
 
                    
                    
                        
- Protective Treatment:
 
                        - TH
 
                    
                    
                    
                    
                    
                        
- QN-QUOTE-REQUEST:
 
                        - true