Schneider Electric XALK178G Emergency Stop Cont. Box
Schneider Electric
$147.00
This Harmony XALK yellow (RAL1021) control station is ideal for a clearly visible emergency shutdown of any machine. This yellow control station enables machine builders to easily add control and signalling functionality on their machines, with permanent modifications or damage to their machine body. It is designed for simple and mass production machines, textiles, packaging, handling small lifting systems, control of garage doors, rolling shutters, smoke extraction vents. It offers emergency stop and emergency switching off functions. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments.
- Control Station Application:
- emergency switching off function || emergency stop function
- Colour Of Cover:
- yellow RAL 1021)
- Shape Of Screw Head:
- cross Philips no 1 || cross pozidriv No 1 || slotted flat à 4 mm || slotted flat à 5.5 mm
- Reach Free Of Svhc:
- Yes
- Environmental Disclosure:
- ENVPEP1806010EN
- Electrical Reliability:
- λ < 10exp(-6) 5 V, 1 mA IEC 60947-5-4 || λ < 10exp(-8) 17 V, 5 mA IEC 60947-5-4
- Device Short Name:
- XALK
- Material:
- polycarbonate
- Reset:
- turn to release
- Connections - Terminals:
- screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
- Sustainable Offer Status:
- Green Premium product
- [Ith] Conventional Free Air Thermal Current:
- 10 A IEC 60947-5-1
- Ambient Air Temperature For Operation:
- -40-70 °C
- [Ui] Rated Insulation Voltage:
- 600 V 3)IEC 60947-1
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-1
- Control Station Composition:
- 1 mushroom head à 40 mm push-button, red 1 NO + 2 NC unmarked
- Warranty:
- 18 months
- Net Weight:
- 0.194 kg
- Mercury Free:
- Yes
- Ip Degree Of Protection:
- IP66 IEC 60529 || IP67 || IP69 || IP69K
- Operating Force:
- 44 N NC + NO changing electrical state
- Toxic Heavy Metal Free:
- Yes
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Contact Operation:
- slow-break
- Shock Resistance:
- 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
- China Rohs Regulation:
- X
- Colour Of Base Of Enclosure:
- light grey RAL 7035)
- Operators Description:
- red unmarked 1 NO + 2 NC
- Resistance To High Pressure Washer:
- 7000000 Pa 55 °C 0.1 m
- Rohs Exemption Information:
- Yes
- Product Destination:
- for XB5 Ã 22 mm control and signalling units
- Mechanical Durability:
- 300000 cycles
- Ambient Air Temperature For Storage:
- -40-70 °C
- Contacts Material:
- silver alloy (Ag/Ni)
- Nema Degree Of Protection:
- NEMA 13 || NEMA 4X
- Tightening Torque:
- 0.8-1.2 N.m IEC 60947-1
- Standards:
- IEC 60947-1 || JIS C 4520 || CSA C22.2 No 14 || IEC 60947-5-1 || IEC 60364-5-53 || ISO 13850 || IEC 60204-1 || IEC 60947-5-4 || IEC 60947-5-5 || UL 508
- Operator Profile:
- 1 mushroom head push-button
- Overvoltage Category:
- class II IEC 60536
- Cable Entry:
- 1 knock-out for cable entry 0-14 mm || 2 knock-outs for Pg 13 cable gland and ISO M20 0-12 mm
- Vibration Resistance:
- 5 gn 12-500 Hz)IEC 60068-2-6
- [Ie] Rated Operational Current:
- 3 A 240 V, AC-15, A600 IEC 60947-5-1 || 6 A 120 V, AC-15, A600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
- Short-Circuit Protection:
- 10 A cartridge fuse gG IEC 60947-5-1
- Product Or Component Type:
- complete control station
- Operating Travel:
- 1.5 mm NC changing electrical state) || 2.6 mm NO changing electrical state) || 4.3 mm total travel)
- Circularity Profile:
- ENVEOLI1806010EN
- Range Of Product:
- Harmony XALK
- Ik Degree Of Protection:
- IK03 IEC 62262
- Positive Opening:
- with IEC 60947-5-1 appendix K
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Electrical Durability:
- 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13,
- Protective Treatment:
- TH
- Datasheet:
- View