Schneider Electric XB5AG33C0 Key Selector Switch
Schneider Electric
$71.57
This key selector switch provides a versatile interface for controlling your machines. It is easily installed into standard 22mm diameter cut-outs and connected to your control circuits with simple screw-clamp connections. It provides a secure manner for authorized staff to switch between process or machine operating modes. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP69, making it ideal for operation in harsh environments.
- Bezel Material:
- plastic colour plated grey
- Head Type:
- standard
- China Rohs Regulation:
- X
- Mercury Free:
- Yes
- Shape Of Signaling Unit Head:
- round
- Contacts Material:
- silver alloy (Ag/Ni)
- Positive Opening:
- without
- Mounting Diameter:
- 22 mm
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Resistance To High Pressure Washer:
- 7000000 Pa 55 °C 0.1 m
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Rohs Exemption Information:
- Yes
- Nema Degree Of Protection:
- NEMA 13 || NEMA 4X
- Depth:
- 96 mm
- Type Of Operator:
- stay put
- Operator Profile:
- key switch
- Key Withdrawal Position:
- center
- Device Presentation:
- complete product
- Device Short Name:
- XB5
- Ip Degree Of Protection:
- IP66 IEC 60529 || IP67
- Short-Circuit Protection:
- 10 A cartridge fuse gG IEC 60947-5-1
- Net Weight:
- 0.831 kg
- Standards:
- JIS C8201-5-1 || IEC 60947-5-1 || IEC 60947-5-4 || IEC 60947-1 || CSA C22.2 No 14 || UL 508 || JIS C8201-1
- Protective Treatment:
- TH
- [Ie] Rated Operational Current:
- 3 A 240 V, AC-15, A600 IEC 60947-5-1 || 6 A 120 V, AC-15, A600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
- Ambient Air Temperature For Storage:
- -40-70 °C
- Contacts Usage:
- standard contacts
- Ik Degree Of Protection:
- IK04 IEC 50102
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-1
- [Ith] Conventional Free Air Thermal Current:
- 10 A IEC 60947-5-1
- Torque Value:
- 0.14 N.m NO changing electrical state
- Mechanical Durability:
- 1000000 cycles
- Terminals Description Iso N°1:
- (13-14)NO
- Height:
- 42 mm
- Connections - Terminals:
- screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
- Shock Resistance:
- 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
- Contacts Type And Composition:
- 2 NO
- Vibration Resistance:
- 5 gn 2-500 Hz)IEC 60068-2-6
- Tightening Torque:
- 0.8-1.2 N.m IEC 60947-1
- Contact Operation:
- slow-break
- Electrical Shock Protection Class:
- class II IEC 60536
- Operator Position Information:
- 3 positions +/- 45°
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Ambient Air Temperature For Operation:
- -40-70 °C
- [Ui] Rated Insulation Voltage:
- 600 V 3)IEC 60947-1
- Type Of Keylock:
- key 455
- Range Of Product:
- Harmony XB5
- Shape Of Screw Head:
- cross Philips no 1 || cross pozidriv No 1 || slotted flat à 4 mm || slotted flat à 5.5 mm
- Width:
- 30 mm
- Electrical Durability:
- 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13,
- Product Or Component Type:
- selector switch
- Product Certifications:
- DNV || UL || CSA || LROS (Lloyds register of shipping) || GL || BV
- Electrical Reliability:
- λ < 10exp(-6) 5 V, 1 mA in clean environment IEC 60947-5-4 || λ < 10exp(-8) 17 V, 5 mA in clean environment IEC 60947-5-4
- Sale Per Indivisible Quantity:
- 1
- Datasheet:
- View