Schneider Electric XB5AW36G5C0 Illuminated Pushbutton

(No reviews yet) Write a Review
SKU:
XB5AW36G5C0
UPC:
3606489760212
Condition:
New
Terminals Description Iso N°1:
(13-14)NO || (21-22)NC
Mounting Diameter:
22 mm
Ambient Air Temperature For Operation:
-40-70 °C
Type Of Operator:
spring return
Operating Travel:
1.5 mm NC changing electrical state) || 2.6 mm NO changing electrical state) || 4.3 mm total travel)
Resistance To Electrostatic Discharge:
6 kV on contact (on metal parts) IEC 61000-4-2 || 8 kV in free air (in insulating parts) IEC 61000-4-2
Depth:
57 mm
Sale Per Indivisible Quantity:
1
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Supply Voltage Limits:
100-132 V AC
Shape Of Signaling Unit Head:
round
Resistance To Electromagnetic Fields:
10 V/m IEC 61000-4-3
Bulb Base:
integral LED
Ambient Air Temperature For Storage:
-40-70 °C
Mechanical Durability:
10000000 cycles
Electrical Reliability:
λ < 10exp(-6) 5 V, 1 mA in clean environment IEC 60947-5-4 || λ < 10exp(-8) 17 V, 5 mA in clean environment IEC 60947-5-4
Product Certifications:
CSA || UL Listed || GL || LROS (Lloyds register of shipping) || DNV || BV
Protective Treatment:
TH
Contacts Type And Composition:
1 NO + 1 NC
Operator Additional Information:
with plain lens
Electrical Durability:
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13,
[Ui] Rated Insulation Voltage:
600 V 3)IEC 60947-1
Operator Profile:
blue flush, unmarked
Fixing Collar Material:
plastic
Device Short Name:
XB5
Standards:
IEC 60947-5-1 || CSA C22.2 No 14 || IEC 60947-5-4 || JIS C8201-5-1 || IEC 60947-1 || UL 508 || JIS C8201-1
Net Weight:
0.056 kg
Contacts Usage:
standard contacts
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Nema Degree Of Protection:
NEMA 13 || NEMA 4X
Service Life:
100000 h at rated voltage and 25 °C
Current Consumption:
14 mA
Shape Of Screw Head:
cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
Electromagnetic Emission:
class B IEC 55011
Ip Degree Of Protection:
IP66 IEC 60529 || IP67
Vibration Resistance:
5 gn 2-500 Hz)IEC 60068-2-6
Height:
42 mm
Resistance To Fast Transients:
2 kV IEC 61000-4-4
Light Source:
universal LED
[Us] Rated Supply Voltage:
110...120 V AC 50/60 Hz
Contact Operation:
slow-break
Contacts Material:
silver alloy (Ag/Ni)
Ik Degree Of Protection:
IK05 IEC 50102
Overvoltage Category:
class II IEC 60536
[Ith] Conventional Free Air Thermal Current:
10 A IEC 60947-5-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Short-Circuit Protection:
10 A cartridge fuse gG IEC 60947-5-1
Important Message:
A change in appearance may be noted on the product but does not affect its use in terms of function and safety. This makes it compatible with our Universal LED blocks
Positive Opening:
with IEC 60947-5-1 appendix K
Cap/Operator Or Lens Colour:
blue
Resistance To High Pressure Washer:
7000000 Pa 55 °C 0.1 m
Bezel Material:
plastic colour plated grey
Signalling Type:
steady
Operating Force:
3.5 N NC changing electrical state || 3.8 N
Device Presentation:
complete product
Shock Resistance:
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Head Type:
standard
Width:
30 mm
[Ie] Rated Operational Current:
3 A 240 V, AC-15, A600 IEC 60947-5-1 || 6 A 120 V, AC-15, A600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
Mercury Free:
Yes
Tightening Torque:
0.8-1.2 N.m IEC 60947-1
Product Or Component Type:
illuminated push-button
Surge Withstand:
1 kV IEC 61000-4-5
Range Of Product:
Harmony XB5
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
China Rohs Regulation:
X
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-1
Connections - Terminals:
screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1
  • Schneider Electric XB5AW36G5C0 Illuminated Pushbutton
  • Schneider Electric XB5AW36G5C0 Illuminated Pushbutton
  • Schneider Electric XB5AW36G5C0 Illuminated Pushbutton
$57.57

Description

This illuminated push-button provides an ergonomic and visual interface for controlling your machines. It is easily installed into a standard 22mm diameter panel cut-outs and connected to control circuits with classic screw-clamp connections. It is clearly distinguishable visually at a distance thanks to a bright and long-lasting LED illumination.