Schneider Electric

Schneider Electric XB5FA3311 Flush Green Flush Cap Pb Wh Mark I 1No

(No reviews yet) Write a Review
SKU:
XB5FA3311
UPC:
3606481360472
Condition:
New
Shock Resistance:
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 || 25 gn 6 ms) 1000 shocks on each axis IEC 60068-2-27
Contact Operation:
slow-break
Overvoltage Category:
class II IEC 60536
Sustainable Offer Status:
Green Premium product
Device Presentation:
complete product
Reach Free Of Svhc:
Yes
Type Of Operator:
spring return
Mechanical Durability:
10000000 cycles
California Proposition 65:
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other repr
[Ui] Rated Insulation Voltage:
600 V 3)IEC 60947-1
Terminals Description Iso N°1:
(13-14)NO
Connections - Terminals:
screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1
Shape Of Signaling Unit Head:
round
Fixing Collar Material:
plastic
Ik Degree Of Protection:
IK06 IEC 50102
Depth:
55 mm
Contacts Material:
silver alloy (Ag/Ni)
Rohs Exemption Information:
Yes
Width:
36.6 mm
Compatibility Code:
XB5
Contacts Usage:
standard contacts
Protective Treatment:
TH
Resistance To High Pressure Washer:
7000000 Pa 55 °C 0.1 m
Vibration Resistance:
5 gn 10-500 Hz)IEC 60068-2-6 || 2 mm peak to peak 2-10 Hz)IEC 60068-2-6
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Electrical Durability:
1000000 cycles AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles DC-13, 0.2
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Tightening Torque:
0.8-1.2 N.m IEC 60947-1
Ambient Air Temperature For Storage:
-40-70 °C
Product Compatibility:
ZBYF2101 || ZBYF4101 || ZBYF6101 || ZBYF6102 || ZBZF32 || ZBZF33 || ZB4FBZ007
Height:
42 mm
Positive Opening:
without
Sale Per Indivisible Quantity:
1
Mercury Free:
Yes
Operating Travel:
2.6 mm NO changing electrical state) || 4.3 mm total travel)
Operator Profile:
green flush, I white)
Toxic Heavy Metal Free:
Yes
Operating Force:
3.8 N NO changing electrical state
[Ie] Rated Operational Current:
3 A 240 V, AC-15, A600 IEC 60947-5-1 || 6 A 120 V, AC-15, A600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Shape Of Screw Head:
cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
China Rohs Regulation:
X
Ambient Air Temperature For Operation:
-40-70 °C
Customizable:
1
Electrical Reliability:
λ < 10exp(-6) 5 V 1 mA in clean environment IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA in clean environment IEC 60947-5-4
Customizable:
no
Ip Degree Of Protection:
IP66 IEC 60529 || IP67 IEC 60529 || IP69 IEC 60529 || IP69K ISO 20653 || Type 13 UL 50 E || Type 12 UL 50 E || Type 4 UL 50 E || Type 4X UL 50 E
Environmental Disclosure:
ENVPEP1710010EN
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-1
Bezel Material:
plastic || dark grey plastic
Standards:
CSA C22.2 No 14 || IEC 60947-5-1 || IEC 60947-5-4 || UL 508 || IEC 60947-1 || JIS C8201-5-1 || CE || JIS C8201-1 || ISO 22196:2011 || ISO 21702
Mounting Diameter:
30.5 mm
Product Or Component Type:
push-button
Range Of Product:
Harmony XB5
Gcr Bridge:
XB5FACUST01
[Ith] Conventional Free Air Thermal Current:
10 A IEC 60947-5-1
Contacts Type And Composition:
1 NO
Head Type:
built-in-flush
Device Short Name:
XB5F
Circularity Profile:
ENVEOLI1710010EN
Product Certifications:
UL Listed || CSA || CCC || EAC
Short-Circuit Protection:
10 A cartridge fuse gG IEC 60947-5-1
Datasheet:
View
$45.00

Description

This flush mounted pushbutton is a part of the Harmony XB5 platic range and is a complete product. The mounting diameter is 30.5 mm. It has a "I" marking in white. Customized marking option is also available through web customization tool in Schneider Electric website. Improved ergonomics and aesthetics due to flush mount design. It comes with antimicrobial characteristics. The contact type is 1NO slow break and the connection terminal is screw clamp. The operator mechanism is spring return, and the push mechanism is flush push. The shape of the head is round and green. The bezel and the fixing collar is plastic. The weight of this pushbutton is 37 grams, height is 42 mm, and width is 36.6 mm. The simplicity of installation, flexibility, and robustness makes it suitable for the majority of industrial segments and applications. With IP66, 67, 69, and 69K, type 13 and 4X, IK03, protection against solid objects, dust, water, and shock is achieved. It is certified with EN/IEC, CE marking, UL, CSA, JIS, NEMA, and marine approvals. Accessories to be ordered separately are available to facilitate the installation. The packaging includes 1 unit of this pushbutton. It can be easily installed to a panel cut out with the help of a cross head screwdriver. Contacts and heads are designed to prevent vibration, helping to ensure secure mounting and wiring. It is eco-friendly and complies with directives such as RoHS, WEEE, etc. related to environmental protection.