- Type Of Start:
- automatic/manual/monitored
- Minimum Output Voltage:
- 5 V relay output
- Circularity Profile:
- ENVEOLI1811003EN
- Mercury Free:
- Yes
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Width:
- 22.5 mm
- Depth:
- 120 mm
- Ip Degree Of Protection:
- IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
- Product Certifications:
- TÃV || cULus
- [Ui] Rated Insulation Voltage:
- 300 V 2)IEC 60947-1
- Mounting Support:
- 35 mm symmetrical DIN rail
- Function Of Module:
- emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches
- China Rohs Regulation:
- X
- Number Of Inputs:
- 0
- Standards:
- IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional
- Input Protection Type:
- internal, electronic
- Minimum Output Current:
- 10 mA relay output
- Ambient Air Temperature For Operation:
- -25-55 °C
- Power Consumption In Va:
- 3.5 VA 24 V AC 50/60 Hz
- Auxiliary Contact Composition:
- 4 NO + 1 NC
- Input Compatibility:
- normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850
- Safety Module Name:
- XPSBAC
- Height:
- 100 mm
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Power Consumption In W:
- 1.5 W 24 V DC
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Product Or Component Type:
- safety module
- Electrical Circuit Type:
- NC pair
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV II IEC 60947-1
- [Ie] Rated Operational Current:
- 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally clo
- Number Of Outputs:
- 0
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Rohs Exemption Information:
- Yes
- Net Weight:
- 0.200 kg
- Local Signalling:
- LED green power power ON || LED red error error || LED yellow state status || LED yellow start1 start input || LED yellow start2 start input
- Sustainable Offer Status:
- Green Premium product
- [Us] Rated Supply Voltage:
- 24 V AC - 15...10 % || 24 V DC - 20...20 %
- Response Time:
- 150 ms at 24 V AC || 80 ms at 24 V DC
- [Ith] Conventional Free Air Thermal Current:
- 0.25
- Range Of Product:
- Harmony Safety Automation
- Synchronisation Time Between Inputs:
- unlimited
- Relative Humidity:
- 5-95 % non-condensing
- Safety Module Application:
- for emergency stop and protective guard applications
- Environmental Disclosure:
- ENVPEP1811003EN
- Safety Reliability Data:
- MTTFd > 30 years for normally open relay contact ISO 13849-1 || Dcavg >= 99 % for normally open relay contact ISO 13849-1 || PFHd = 0.95E-09 for normally open relay contact ISO 13849-1 || HFT = 1 for normally open relay contact IEC 62061 || PFHd = 0.
- Safety Level:
- can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay c
- Connections - Terminals:
- removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable
- Terminal Identifier:
- power supply
- Associated Fuse Rating:
- 10 A gG NO relay output circuit IEC 60947-1