Local Signalling:
LED green power power ON || LED red error error || LED yellow state 1 safety output instantaneous || LED yellow state 2 safety output delayed || LED yellow start 1 start || LED yellow start 2 start || LED yellow S12 safety input S12 || LED yellow S22
Type Of Start:
automatic/manual/monitored
Product Certifications:
TÜV || cULus
[Us] Rated Supply Voltage:
24 V AC - 15...10 % || 24 V DC - 20...20 %
Input Compatibility:
normally closed circuit ISO 14119 || mechanical contact ISO 14119 || OSSD pair IEC 61496-1-2 || normally closed circuit ISO 13850 || 3-wire proximity sensors PNP
Ambient Air Temperature For Operation:
-25-55 °C
[Ith] Conventional Free Air Thermal Current:
0
Connections - Terminals:
removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable
Mounting Support:
35 mm symmetrical DIN rail
Rohs Exemption Information:
Yes
Maximum Response Time On Input Open:
20 ms
Auxiliary Contact Composition:
2 NO immediate || 1 NO configurable
[Ie] Rated Operational Current:
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
Ambient Air Temperature For Storage:
-25-85 °C
Relative Humidity:
5-95 % non-condensing
Minimum Output Voltage:
24 V relay output
Net Weight:
0.350 kg
Height:
100 mm
Sustainable Offer Status:
Green Premium product
Electrical Circuit Type:
NC pair || OSSD pair
Product Or Component Type:
safety module
[Ui] Rated Insulation Voltage:
250 V 2)IEC 60947-1
Power Consumption In Va:
5 VA 24 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage:
4 kV II IEC 60947-1
Safety Reliability Data:
MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 0.98E-09 for SS0 ISO 13849-1 || PFHd = 0.96E-09 for SS1 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 0.98E-09 for SS0 IEC 62061 || PFHd = 0.96E-09 for SS1 IEC 62061 || SFF > 99% IEC 62
China Rohs Regulation:
X
Width:
22.5 mm
Safety Level:
can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay c
Minimum Output Current:
20 mA relay output
Environmental Disclosure:
ENVPEP1811003EN
Maximum Line Resistance:
500 Ohm
Depth:
120 mm
Power Consumption In W:
2 W 24 V DC
Safety Module Application:
for emergency stop and protective guard applications || for OSSD monitoring
Standards:
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional
Range Of Product:
Harmony Safety Automation
Ip Degree Of Protection:
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Synchronisation Time Between Inputs:
0.5 s || 2 s
Number Of Outputs:
3 on/off configurable pulsed output
Function Of Module:
emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE)
Input Protection Type:
internal, electronic
Associated Fuse Rating:
6 A gG NO relay output circuit IEC 60947-1
Mercury Free:
Yes
Input/Output Type:
semiconductor output 24 V DC, 20 mA Z1, not safety-related
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Time Delay Range:
0...900 s off
Circularity Profile:
ENVEOLI1811003EN
Number Of Inputs:
2 positive safety input 24 V DC 5
Safety Module Name:
XPSBAT
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Catalog:
View
Datasheet:
View
  • Schneider Electric XPSBAT12A1AP Estop, Guard, Ossd, 24 V Screw
  • Schneider Electric XPSBAT12A1AP Estop, Guard, Ossd, 24 V Screw
  • Schneider Electric XPSBAT12A1AP Estop, Guard, Ossd, 24 V Screw
$420.00

Description

This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, RFID safety switch and Safety light curtain. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 safety inputs, 3 control outputs, 2 NO immediate, 3 NO configurable and 1 NC configurable safety output, 1 diagnostic output. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÜV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Basic offers the most optimised solution for applications with hardwired safety modules.
View AllClose