This product is part of preventa XPCMC configurable safety controller range. It is a configurable safety controller. It is supplied with 24 V DC. It has 16 safety inputs. It conforms to Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1, PLE safety level conforming to EN/ISO 13849-1 and SIL 3 level conforming to IEC 61508. It embeds 1 RJ45 port for a serial link communication with Modbus protocol. The transmission rate are 1200bps, 2400 bps, 4800bps, 9600bps or 19200bps. This product measures 153mm depth, 151.5mm height, and 74mm width. It weighs 0.82kg. This safety controller is designed for monitoring multiple safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This product is certified by CSA, UL and TÜV. It conforms to EN 954-1/EN/ISO 13849-1, EN/IEC 61496-1, IEC 61508, EN/IEC 60204-1, EN 1760-1/ISO 13856-1, EN 574/ISO 13851 and EN/IEC 60947-5-1 standards. The Safety controller XPSMC is configurable and addressable using software XPSMCWIN running on a PC and using a USB/RJ45 cable type TCSMCNAM3M002P to connect to the safety controller. It installs with a mounting plate for mounting on rail. Preventa XPSMC configurable safety controller is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN ISO 13849-1 and SIL3 EN/IEC 61508. The configurable safety controller consists of 6 variants with 16 or 32 digital inputs and 8 digital outputs and communication possibilities of Modbus RTL Serial, Profibus DP and CANopen.
- Safety Module Name:
- XPSMC
- Rohs Exemption Information:
- Yes
- Parity:
- even Modbus || no Modbus || odd Modbus
- Warranty:
- 18 months
- Sustainable Offer Status:
- Green Premium product
- Number Of Inputs:
- 16
- Number Of Addresses:
- 1-247 Modbus
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Safety Use Category:
- category 4 maximum EN 954-1/EN/ISO 13849-1 || PLE maximum ISO 13849-1 || SIL 3 maximum IEC 61508
- Ip Degree Of Protection:
- IP20 conforming to IEC 60529
- Product Or Component Type:
- configurable safety controller
- Exchange Size:
- 14 words
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
- Range Of Product:
- Preventa Safety automation
- [Uc] Control Circuit Voltage:
- 28.8 V
- Safety Level:
- can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 || can reach SIL 3 IEC 61508
- Product Certifications:
- TÃV || UL || CSA
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Local Signalling:
- 30 LEDs
- Depth:
- 153 mm
- Standards:
- EN 574/ISO 13851 || EN 1760-1/ISO 13856-1 || IEC 61496-1 || IEC 60204-1 || IEC 61508 || IEC 60947-5-1 || EN 954-1/EN/ISO 13849-1
- Function Of Module:
- dynamic monitoring of hydraulic valves on linear presses || eccentric press || emergency stop monitoring, with or without time delay, 1 or 2-channel wiring || enabling switch monitoring, 2 or 3 contacts || foot switch monitoring || guard monitoring f
- Type Of Start:
- configurable
- Response Time:
- configurable : 20 ms or 30 ms with software XPSMCWIN
- Output Thermal Current:
- 4 A for both outputs simultaneously || 6 A for 1 output and 2 A for the other relay output
- Pvc Free:
- Yes
- Mercury Free:
- Yes
- Synchronisation Time Between Inputs:
- depending on configuration selected
- Associated Fuse Rating:
- 16 A gL power supply || 4 A gL relay output || 6 A fast blow relay output
- Breaking Capacity:
- 2 A 24 V static output circuit || 1.5 A 24 V DC-13)50 ms relay output
- [Ui] Rated Insulation Voltage:
- 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
- Communication Port Protocol:
- Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Ambient Air Temperature For Operation:
- -10-55 °C
- Ambient Air Temperature For Storage:
- -25-85 °C
- Minimum Output Current:
- 10 mA relay output
- Circularity Profile:
- ENVEOLI1406025EN
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Net Weight:
- 0.82 kg
- China Rohs Regulation:
- X
- Input Protection Type:
- external fuse 16 A
- Breaking Capacity:
- 180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output
- Maximum Line Resistance:
- 100 Ohm <2000 m
- Mounting Support:
- mounting plate
- Height:
- 151.5 mm
- Method Of Access:
- slave
- Supported Modbus Function:
- 01 8-bit output data/32-bit input data || 02 32-bit input data/8-bit output data || 03 information and errors
- [Ith] Conventional Free Air Thermal Current:
- 16 A relay output || 6.5 A static output circuit
- [Us] Rated Supply Voltage:
- 24 V DC - 20...20 %
- Power Consumption In W:
- 12 W
- Minimum Output Voltage:
- 17 V relay output
- Width:
- 74 mm
- Environmental Disclosure:
- ENVPEP1406025EN
- Output Type:
- 2 relays, 2 NO contacts (4 NO total) || solid state, 6, volt-free
- Data Format:
- 1 start bit/8 data bits || 1 stop bit even or odd || 2 stop bits without parity || RTU (Remote Terminal Unit) mode
- Catalog:
- View
- Datasheet: