Schneider Electric

Schneider Electric XPSMC32ZC Safety Controller With 32 Imputs

(No reviews yet) Write a Review
SKU:
XPSMC32ZC
UPC:
3389119010283
Condition:
New
Net Weight:
0.84 kg
Associated Fuse Rating:
16 A gL power supply || 4 A gL relay output || 6 A fast blow relay output
Pvc Free:
Yes
[Ith] Conventional Free Air Thermal Current:
16 A relay output || 6.5 A static output circuit
Ambient Air Temperature For Storage:
-25-85 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Ambient Air Temperature For Operation:
-10-55 °C
China Rohs Regulation:
X
[Uimp] Rated Impulse Withstand Voltage:
4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
Minimum Output Current:
10 mA relay output
Environmental Disclosure:
ENVPEP1406025EN
[Ui] Rated Insulation Voltage:
300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
Mercury Free:
Yes
Number Of Addresses:
1-127 CANopen || 1-247 Modbus
Parity:
even Modbus || no Modbus || odd Modbus
Mounting Support:
mounting plate
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Sustainable Offer Status:
Green Premium product
Output Type:
2 relays, 2 NO contacts (4 NO total) || solid state, 6, volt-free
Range Of Product:
Preventa Safety automation
Warranty:
18 months
Type Of Start:
configurable
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Input Protection Type:
external fuse 16 A
Product Certifications:
UL || TÜV || CSA
Standards:
IEC 60947-5-1 || EN 574/ISO 13851 || EN 1760-1/ISO 13856-1 || IEC 61496-1 || IEC 61508 || EN 954-1/EN/ISO 13849-1 || IEC 60204-1
Response Time:
configurable : 20 ms or 30 ms with software XPSMCWIN
Height:
151.5 mm
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Function Of Module:
dynamic monitoring of hydraulic valves on linear presses || eccentric press || emergency stop monitoring, with or without time delay, 1 or 2-channel wiring || enabling switch monitoring, 2 or 3 contacts || foot switch monitoring || guard monitoring f
Maximum Line Resistance:
100 Ohm <2000 m
Communication Port Protocol:
CANopen 1 SUB-D 9-pin male, serial link 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps or 1 Mbps || Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
Minimum Output Voltage:
17 V relay output
Data Format:
1 start bit/8 data bits || 1 stop bit even or odd || 2 stop bits without parity || RTU (Remote Terminal Unit) mode
[Us] Rated Supply Voltage:
24 V DC - 20...20 %
Output Thermal Current:
4 A for both outputs simultaneously || 6 A for 1 output and 2 A for the other relay output
Local Signalling:
48 LEDs
Number Of Inputs:
32
Exchange Size:
14 words
Depth:
153 mm
Power Consumption In W:
12 W
Supported Modbus Function:
01 8-bit output data/32-bit input data || 02 32-bit input data/8-bit output data || 03 information and errors
Breaking Capacity:
180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output
Circularity Profile:
ENVEOLI1406025EN
Safety Level:
can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 || can reach SIL 3 IEC 61508
Safety Module Name:
XPSMC
Width:
74 mm
Breaking Capacity:
2 A 24 V static output circuit || 1.5 A 24 V DC-13)50 ms relay output
Safety Use Category:
category 4 maximum EN 954-1/EN/ISO 13849-1 || PLE maximum ISO 13849-1 || SIL 3 maximum IEC 61508
Synchronisation Time Between Inputs:
depending on configuration selected
[Uc] Control Circuit Voltage:
28.8 V
Product Or Component Type:
configurable safety controller
Method Of Access:
slave
Catalog:
View
Datasheet:
View
$2,723.00

Description

This product is part of preventa XPCMC configurable safety controller range. It is a configurable safety controller. It is supplied with 24 V DC. It has 32 safety inputs. It conforms to Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1, PLE safety level conforming to EN/ISO 13849-1 and SIL 3 level conforming to IEC 61508. It embeds 1 RJ45 port for serial link communication with Modbus protocol. Transmission rate are 1200/2400/4800/9600 and 19200bps, and another SUB-D 9-pin male port for CANopen communication. Transmission rate are 20/50/125 and 250kbps. This product measures 153mm depth, 151.5mm height, and 74mm width. It weighs 0.84kg. This safety controller is designed for monitoring multiple safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This product is certified by CSA, UL and TÜV. It conforms to EN 954-1/EN/ISO 13849-1, EN/IEC 61496-1, IEC 61508, EN/IEC 60204-1, EN 1760-1/ISO 13856-1, EN 574/ISO 13851 and EN/IEC 60947-5-1 standards. The Safety controller XPSMC is configurable and addressable using software XPSMCWIN running on a PC and using a USB/RJ45 cable type TCSMCNAM3M002P to connect to the safety controller. It installs with a mounting plate for mounting on rail. Preventa XPSMC configurable safety controller is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN ISO 13849-1 and SIL3 EN/IEC 61508. The configurable safety controller consists of 6 variants with 16 or 32 digital inputs and 8 digital outputs and communication possibilities of Modbus RTL Serial, Profibus DP and CANopen.
View AllClose