Schneider Electric XPSUAF13AP Safety Module Uaf Cat.4 24V Screw

(No reviews yet) Write a Review
SKU:
XPSUAF13AP
UPC:
3606489601614
Condition:
New
Number Of Inputs:
2 safety input 24 V DC 5
Depth:
120 mm
Safety Module Name:
XPSUAF
China Rohs Regulation:
X
Width:
22.5 mm
Local Signalling:
for power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S22 LED (yellow)
Sustainable Offer Status:
Green Premium product
Minimum Output Voltage:
15 V relay output
Maximum Line Resistance:
500 Ohm
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Function Of Module:
emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE
Maximum Response Time On Input Open:
20 ms
Net Weight:
0.200 kg
Relative Humidity:
5-95 % non-condensing
Standards:
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional
[Uimp] Rated Impulse Withstand Voltage:
4 kV II IEC 60947-1
Safety Module Application:
monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring
Safety Reliability Data:
MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 1.13E-09 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 1.13E-09 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 1.13E-09 IEC 61508-1 || SFF > 99% IEC 61508-1 || type =
[Ith] Conventional Free Air Thermal Current:
0.333333333333333
Pvc Free:
Yes
Minimum Output Current:
10 mA relay output
Product Certifications:
TÜV || cULus
Synchronisation Time Between Inputs:
0.5 s || 2 s || 4 s
[Us] Rated Supply Voltage:
24 V AC - 15...10 % || 24 V DC - 20...20 %
Ip Degree Of Protection:
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
Circularity Profile:
ENVEOLI1811003EN
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Type Of Start:
automatic/manual/monitored
Associated Fuse Rating:
10 A gG NO relay output circuit IEC 60947-1
Power Consumption In W:
2.0 W 24 V DC
Electrical Circuit Type:
NC pair || PNP pair || antivalent pair || OSSD pair
Mounting Support:
35 mm symmetrical DIN rail
Auxiliary Contact Composition:
3 NO
Ambient Air Temperature For Storage:
-25-85 °C
[Ie] Rated Operational Current:
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
Product Or Component Type:
safety module
[Ui] Rated Insulation Voltage:
250 V 2)IEC 60947-1
Power Consumption In Va:
5.0 VA 24 V AC 50/60 Hz
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Input/Output Type:
semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
Height:
100 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Connections - Terminals:
removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable sc
Range Of Product:
Harmony Safety Automation
Safety Level:
can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061 || can reach SIL 3 IEC 61508
Input Protection Type:
internal, electronic
Input Compatibility:
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Environmental Disclosure:
ENVPEP1811003EN
Number Of Outputs:
3 on/off configurable pulsed output
  • Schneider Electric XPSUAF13AP Safety Module Uaf Cat.4 24V Screw
  • Schneider Electric XPSUAF13AP Safety Module Uaf Cat.4 24V Screw
  • Schneider Electric XPSUAF13AP Safety Module Uaf Cat.4 24V Screw
$307.45

Description

This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch or Safety light curtain. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 safety inputs, 3 ON/OFF configurable pulsed outputs, 3 NO safety outputs, and 1 solid state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILC L 3 conforming to IEC 62061, and SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
View AllClose