- Function Of Module:
- safety output extension
- Range Of Product:
- Harmony Safety Automation
- Auxiliary Contact Composition:
- 4 NO redundant || 2 NC single
- Rohs Exemption Information:
- Yes
- [Ith] Conventional Free Air Thermal Current:
- 0.333333333333333
- Relative Humidity:
- 5-95 % non-condensing
- Power Consumption In Va:
- 3.5 VA 24 V AC 50/60 Hz
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Ip Degree Of Protection:
- IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
- Safety Module Name:
- XPSUEP
- Input Protection Type:
- internal, electronic
- Depth:
- 120 mm
- Electrical Circuit Type:
- addition to Preventa XPSU base module
- Power Consumption In W:
- 1.5 W 24 V DC
- Associated Fuse Rating:
- 10 A gG NO relay output circuit IEC 60947-1 || 4 A gG NC relay output circuit IEC 60947-1
- Maximum Response Time On Input Open:
- 20 ms
- Safety Level:
- can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay c
- China Rohs Regulation:
- X
- Number Of Inputs:
- 0 extension bus 24 V DC 5
- Width:
- 22.5 mm
- Maximum Line Resistance:
- 60 Ohm
- Safety Reliability Data:
- MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 0.97E-09 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 0.97E-09 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 0.97E-09 IEC 61508-1 || SFF > 99% IEC 61508-1 || type =
- Standards:
- IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional
- Height:
- 100 mm
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Mercury Free:
- Yes
- Safety Module Application:
- for extending number of safety contacts
- Mounting Support:
- 35 mm symmetrical DIN rail
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV II IEC 60947-1
- Input Compatibility:
- normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
- Circularity Profile:
- ENVEOLI1811003EN
- Product Or Component Type:
- safety module
- Environmental Disclosure:
- ENVPEP1811003EN
- Minimum Output Current:
- 10 mA relay output
- Ambient Air Temperature For Storage:
- -25-85 °C
- Sustainable Offer Status:
- Green Premium product
- Product Certifications:
- TÃV || cULus
- [Ie] Rated Operational Current:
- 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
- Local Signalling:
- for power ON LED (green) || for error LED (red) || for safety output status LED (yellow)
- [Ui] Rated Insulation Voltage:
- 250 V 2)IEC 60947-1
- Connections - Terminals:
- removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable
- Minimum Output Voltage:
- 12 V relay output
- Pvc Free:
- Yes
- [Us] Rated Supply Voltage:
- 24 V AC - 15...10 % || 24 V DC - 20...20 %
- Net Weight:
- 0.200 kg
- QN-QUOTE-REQUEST:
- true