null

Automation Distribution helps you design, build, and support high-performance automation cells with SMC, Universal Robots, WAGO, Turck, PULS, Zebra, Yaskawa and more.

Small Machine Guard Door Safety Kit – Vital + DYNlink Sensors + Contactors

ABB
SKU:
ADI-Safety-Door-Kit-1
$2,639.00
Condition:
New
Current Stock:

Protect small machines and cells with a complete ABB DYNlink safety package engineered for access doors or hatches. This bundle combines the Vital 1 safety controller, Eden DYN non‑contact door monitoring, AFS safety contactors, Smile reset, and all required ABB cabling and accessories so you can implement a high‑performance safety circuit with minimal design time.

ABB Small Machine Guard Door Safety Kit with Vital 1 safety controller and Eden DYN non‑contact door switches. Ideal for CNC machines, robotic cells, and packaging equipment that need reliable guard door monitoring and safe stop. Pre‑engineered DYNlink architecture reduces wiring, speeds installation, and simplifies compliance with ISO 13849 and IEC 62061.

This kit is built entirely from ABB components that are designed to work together in a DYNlink safety loop.

  • 1× Vital 1 Safety Controller
    Compact safety controller with DYNlink technology for monitoring multiple safety devices in series, providing dual safety outputs for controlling contactors or other final elements.

  • 1× Adam DYN‑Info M12‑5 Safety Sensor
    Dynamic non‑contact safety sensor (Eden Adam) with M12‑5 connection for reliable door and guard position monitoring in a DYNlink loop.

  • 1× Eva General Code Actuator
    General coded Eva actuator for Eden, suitable where interchangeability and easy replacement are desired.

  • 1× Eva Unique Code Actuator
    High‑level coded Eva actuator that pairs uniquely with its Adam for increased protection against tampering or bypass.

  • 1× Tina 4A Connection Block
    Four‑port DYNlink M12‑5 connection block for simple series connection of multiple Eden sensors and other DYNlink devices to the Vital controller.

  • 1× Safety Contactor, 3P, 2NO/2NC, 24 VDC
    Safety‑rated 3‑pole contactor with mechanically linked contacts, dedicated for safety applications and ideal as the power switching element in the safety chain.

  • 1× Smile 11 RA Reset Button
    Compact reset device with indicator and M12 connection, used for safe manual reset of the safety circuit at the operator position.

Included ABB cables and accessories

All necessary ABB cabling is included so you can quickly wire the safety loop and field devices.

  • 1× M12‑C00612 0.6 m Cable, 5×0.34, Female
    Short M12‑5 female cable for close‑coupled sensor or device connections.

  • 1× M12‑C312 3 m Cable, 5×22 AWG, Female/Male
    Standard‑length M12‑5 F/M cordset for connecting Eden or Smile devices to Tina 4A.

  • 1×  M12‑C61 6 m Cable, 5×0.34
    Longer M12‑5 cable to reach more distant doors or reset locations.

  • 1× C5 Cable 5×0.34, 100 m Spool
    Panel and field wiring cable for extending DYNlink and auxiliary connections where pre‑made cordsets are not ideal.

  • 1× Tina 1A Plug for Tina 4/8
    Plug accessory for unused M12 ports on Tina 4A, helping maintain proper connection and environmental protection.

How this kit is used

This Small Machine Guard Door Safety Kit is ideal for CNC machines, small assembly cells, packaging stations, and other compact equipment that require monitored access doors or removable guards. Vital 1 supervises the DYNlink loop through Tina 4A, Eden Adam/Eva monitors each guard, the AFS09Z contactor safely disconnects power when a fault or open guard is detected, and the Smile 11 RA provides a clear, local reset interface once the area is verified safe.

 

What Manufacturing Professionals Want to Know

1. Does this kit meet my safety level and standards?

  • Vital 1 is designed to be used in safety circuits up to high performance levels when wired according to ABB’s guidelines and relevant standards (ISO 13849, IEC 62061).

  • Eden DYN (Adam sensor + Eva actuator) provides non‑contact guard door monitoring with coded actuation, which supports ISO 14119 requirements for interlocking and manipulation resistance.

  • The AFS09Z safety contactor offers mechanically linked contacts for reliable feedback and power isolation of motors or actuators.

Your final achievable PL/SIL depends on your specific machine, stop time, wiring, and diagnostic coverage. Use this kit as the core of your safety design and verify with a formal risk assessment.

2. How many doors can I protect, and how scalable is it?

  • The kit is optimized for small machines or cells with up to four access doors or hatches.

  • Vital 1 with DYNlink can supervise multiple devices in series, so you can often add additional Eden DYN sensors without adding another controller, as long as you stay within ABB’s device and cable limits.

  • The Tina 4A connection block and supplied M12 cables are chosen to make daisy‑chaining additional doors straightforward.

3. How difficult is installation and troubleshooting?

  • Pre‑terminated M12 cables for Adam, Eva, Tina 4A, and Smile 11 RA reduce panel terminations and wiring errors.

  • The C5 multi‑core cable spool lets you extend runs where needed without changing the safety concept.

  • Vital 1, Tina 4A, and AFS09Z provide clear status indication and contact feedback, helping maintenance quickly locate which door or device is preventing restart.

  • “Can I identify which door is open?” Yes, by using the built‑in diagnostics on Vital and Eden, and by wiring contact feedback from the AFS contactor, maintenance can quickly see which device or guard is blocking a restart.

4. How does this compare to traditional hardwired relays?

  • With DYNlink, multiple safety devices share a single dynamic loop back to Vital 1, reducing I/O points and wiring compared to separate dual‑channel relay circuits at each door.

  • Adding a door usually means adding one Adam sensor, one Eva actuator, and an M12 cable, instead of re‑engineering multiple relay channels.

  • You still get hardwired, relay‑based outputs to the AFS contactor, which many plants prefer for simplicity and clear separation of safety power.