WAGO 2006-1621/1000-859 2-Conductor Fuse Terminal Block with Pivoting Fuse Holder for 5 x 30 mm Fuse
WagoThe WAGO 2006 TOPJOB S series feed-through terminal block is a gray, single-level unit featuring a fused-disconnect lever type for 5x30mm fuses, with a blown-fuse LED indicator for 380-500Vdc. It includes side and center marking slots and accommodates one feed-through pole with two push-in wire connections (1+1) for wire sizes ranging from 0.5mm² to 10mm² (#20AWG to #8AWG). The terminal block has a nominal cross-section of 6mm², a rated current of 10A, and utilizes Push-in CAGE CLAMP spring connections. It is designed for mounting on a DIN-35 rail (35 x 15 / 35 x 7.5) with a width of 7.5mm, equivalent to model 200616211000859.
- actuation type:
- Push-in || Operating tool
- approvals per:
- C22.2 No 158
- type of fuse:
- Cylindrical fuse 5 x 30 mm
- color:
- Gray
- connectable conductor materials:
- Copper
- connection technology:
- Push-in CAGE CLAMP
- country of origin sales organisation germany:
- DE
- depth from upper edge of din rail:
- 59 mm / 2.323 inch
- design:
- Horizontal type
- fine stranded conductor:
- 0.5 10 mm / 20 8 AWG
- fine stranded conductor with ferrule push in termination:
- 2.5 6 mm / 16 10 AWG
- fine stranded conductor with insulated ferrule:
- 0.5 6 mm / 20 10 AWG
- fire load:
- 0.332 MJ
- flammability class per ul94:
- V0
- height:
- 96.3 mm / 3.791 inch
- insulation material:
- Polyamide (PA66)
- legend ratings:
- (III / 3) Overvoltage category III / Pollution degree 3
- marking level:
- Center/side marking
- mounting type:
- DIN-35 rail
- nominal cross section:
- 6 mm
- nominal voltage iii 3:
- 800 V
- note conductor cross section:
- Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
- note on rated current 1:
- Leakage current in case of a blown fuse: LED 2 mA
- operation status indicator:
- 380 500 V
- packaging type:
- Box
- rated current:
- 0.416666666666667
- rated current csa use group b:
- 15 A
- rated current csa use group c:
- 15 A
- rated current ul use group b:
- 15 A
- rated current ul use group c:
- 15 A
- rated surge voltage iii 3:
- 8 kV
- rated voltage csa use group b:
- 600 V
- rated voltage csa use group c:
- 600 V
- rated voltage ul use group b:
- 500 V
- rated voltage ul use group c:
- 500 V
- ratings note:
- Electrical ratings are given by the fuse and blown fuse indication.
- ratings per:
- IEC/EN 60947-7-3
- solid conductor:
- 0.5 10 mm / 20 8 AWG
- solid conductor push in termination:
- 1 10 mm / 14 8 AWG
- strip length:
- 13 15 mm / 0.51 0.59 inch
- weight:
- 25.100 g
- width:
- 7.5 mm / 0.295 inch
- wiring direction:
- Front-entry wiring