dielectric strength control load circuit ac 1 min:
3.75 kVrms
fine stranded conductor:
0.34 2.5 mm / 22 14 AWG
fire load:
0.000 MJ
height:
94 mm / 3.701 inch
input voltage range high level:
AC/DC 90 138 V
input voltage range low level:
AC/DC 0 25 V
inrush current resistive max:
(AC) 15 A / 0.01 s
leakage current at rated voltage:
¤ 1 A
limiting continuous current:
0.125
mounting type:
DIN-35 rail
nominal input current at un:
3.9 mA
nominal input voltage un:
AC/DC 115 V
nominal output voltage:
DC 24 V
note:
Optocouplers and solid state relays are designed for use in signal processing networks, which are not supplied by the low-voltage power supply networks.
operating altitude max:
2000 m
output voltage range:
DC 0 30 V
packaging type:
Box
processing temperature:
-25 +50 C
protection type:
IP20
relative humidity:
5 95 % (no condensation permissible)
solid conductor:
0.34 2.5 mm / 22 14 AWG
standards specifications:
EN 61000-6-2 || EN 61000-6-3 || EN 61373 || EN 61010-2-201 || UL 508