WAGO 286-352/004-000 relay module, 4-pole, 24V DC, 5A, gray
Wago
$134.80
Relay module; Relay with 4 make contacts (4a); with extended input voltage and temperature range
Technical Data
- Nominal input voltage U<sub>N</sub>: DC 24 V
- Input voltage range: -30 +25 %
- Nominal input current at U<sub>N</sub>: 8.5 mA
- Number of make contacts/switch on contacts: 4
- Contact material (relay): AgNi + Au
- Limiting continuous current: 5 A
- Max. switching voltage: AC 250 V
- Pull-in time (typ.): 10 ms
- Drop-out time (typ.): 5 ms
- Bounce time (typ): 2 ms
- Rated voltage: 250 V
- Rated impulse voltage: 2.5 kV
- Pollution degree: 2
- Dielectric strength, control/load circuit (AC, 1 min): 1.5 kVrms
- Protection class: IP20
Geometrical Data
- Width: 25 mm / 0.984 inch
- Height from upper-edge of DIN-35 rail: 82.5 mm / 3.248 inch
- Depth: 52 mm / 2.047 inch
Mechanical Data
- Type of mounting: Pluggable module for carrier terminal blocks
Material Data
- Color: gray
- Fire load: 14.881 MJ
- Weight: 40.100 g
Environmental Requirements
- Surrounding air (operating) temperature at U<sub>N</sub>: -25 70 C
- Surrounding air (storage) temperature: -25 70 C
- Processing temperature: -25 +50 C
Standards and specifications
- Standards/specifications: EN 60664-1
Commercial data
- Packaging type: BOX
- Country of origin: DE
- GTIN: 4055143104760
- Customs Tariff No.: 85364900990
The WAGO 286 series replacement plug-in relay is a 4-pole (4P) electromechanical device with a control voltage range of 16.8-30Vdc (nominally 24Vdc) and features 4 normally open (4NO / 4PST-NO) contacts. It has a rated current of 50mA at 30Vdc (DC-13) to prevent the evaporation of the Gold flash. The relay is designed for plug-in mounting with IP20 protection and utilizes hard gold-plated silver-nickel (AgNi + Au) contacts. It is equivalent to the model number 286352004000.
- bounce time typ:
- 2 ms
- color:
- Gray
- contact material relay:
- AgNi + Au
- country of origin sales organisation germany:
- DE
- depth:
- 52 mm / 2.047 inch
- dielectric strength control load circuit ac 1 min:
- 1.5 kVrms
- drop out time typ:
- 5 ms
- fire load:
- 14.883 MJ
- height from upper edge of din rail:
- 82.5 mm / 3.248 inch
- input voltage range:
- -30 +25 %
- limiting continuous current:
- 0.208333333333333
- mounting type:
- Pluggable module for receptacle terminal blocks
- nominal input current at un:
- 8.5 mA
- nominal input voltage un:
- DC 24 V
- number of make switch on contacts:
- 4
- operating altitude max:
- 2000 m
- packaging type:
- Box
- pollution degree:
- 2
- processing temperature:
- -25 +50 C
- protection type:
- IP20
- pull in time typ:
- 10 ms
- rated surge voltage:
- 2.5 kV
- rated voltage:
- 250 V
- relative humidity:
- 5 85 % (no condensation permissible)
- standards specifications:
- EN 60664-1
- surrounding air temperature operation at un:
- -25 70 C
- surrounding air temperature storage:
- -25 70 C
- switching voltage max:
- AC 250 V
- weight:
- 40.100 g
- width:
- 25 mm / 0.984 inch