achievable safety classes:
4 x Cat. 2/SIL 2 or 2 x Cat. 4/SIL 3
actuator connection:
4 x (Fail-safe output with test pulse)
color:
Yellow
configuration options:
PROFIsafe address adjustable via DIP switch or engineering software
conformity marking:
CE
connection technology inputs outputs:
16 x CAGE CLAMP
connection type 1:
Inputs/outputs
country of origin sales organisation germany:
DE
current carrying capacity power jumper contacts:
0.416666666666667
depth:
67.8 mm / 2.669 inch
depth from upper edge of din rail:
60.6 mm / 2.386 inch
emc emission of interference:
Per EN 61000-6-4
emc immunity to interference:
Per EN 61000-6-2
exposure to pollutants:
Per IEC 60068-2-42 and IEC 60068-2-43
fine stranded conductor:
0.08 2.5 mm / 28 14 AWG
fire load:
2.309 MJ
height:
100 mm / 3.937 inch
housing material:
Polycarbonate: polyamide 6.6
indicators:
LED (A-H) green: Status I1 I8: LED (I-K) red: internal, external error
input characteristic:
Clock sensitive
input current per channel for signal 1 typ:
2.2 mA
input response times min max:
Ton (L->H) = 13 ms 71 ms: toff (H->L) = 13 ms 26 ms: plus 2 x local bus runtime: plus 2 x fieldbus runtime: plus PLC runtime
isolation:
500 V system/field
load reactances max:
Capacitive 2 nF: inductive corresponding to DC 13
load type of switching frequency:
Resistive load
mounting position:
Horizontal (standing/lying): vertical
mounting type:
DIN-35 rail
number of digital inputs:
4
number of digital outputs:
4
number of incoming power jumper contacts:
2
number of outgoing power jumper contacts:
2
operating altitude:
0 2000 m
output circuit design:
Power outputs
output response times max:
Ton (L->H) = 13 ms: toff (H->L) = 13 ms: plus 2 x local bus runtime: plus 2 x fieldbus runtime: plus PLC runtime
packaging type:
Box
permissible h2s contaminant concentration at a relative humidity 75:
10 ppm
permissible so2 contaminant concentration at a relative humidity 75:
25 ppm
pollution degree 5:
2 per IEC 61131-2
power consumption 5 v system supply:
55 mA
proof test interval:
10 Years
protection type:
IP20
relative humidity without condensation:
0.95
sensor connection:
4 x (Fail-safe input with test pulse)
shock resistance:
15g per IEC 60068-2-27
signal type:
Voltage
solid conductor:
0.08 2.5 mm / 28 14 AWG
strip length:
8 9 mm / 0.31 0.35 inch
supply voltage field:
24 VDC (-15 +20 %): via power jumper contacts (power supply via blade contact: transmission via spring contact)
supply voltage system:
5 VDC: via data contacts
surrounding air temperature operation:
0 55 C
surrounding air temperature storage:
-40 85 C
switching frequency max:
5 Hz: Resistive load
switching frequency max 2:
0.1 Hz: Inductive load per IEC 947-5-1, DC 13
switching frequency max 3:
5 Hz: Inductive load per IEC 947-5-1, DC 13: with recovery diodes
total number of channels module:
8
vibration resistance:
Per IEC 60068-2-6
voltage signal type:
24 VDC
weight:
101.193 g
width:
24 mm / 0.945 inch
  • Wago 750-665/000-001
  • Wago 750-665/000-001
  • Wago 750-665/000-001
$774.80

Description

Fail-safe 4/4 channel digital input/output; 24 VDC; 0.5 A; PROFIsafe

Technical Data
  • Number of digital inputs: 4
  • Number of digital outputs: 4
  • Total number of channels (module): 8
  • Achievable safety classes: 4 x Cat. 2/SIL 2 or 2 x Cat. 4/SIL 3
  • Type of signal: Voltage
  • Type of signal voltage: DC 24 V
  • Sensor connection: 4 x (sicherer Eingang mit Testpuls)
  • Actuator connection: 4 x (fail-safe output with test pulse)
  • Input characteristic: clock sensitive
  • Input current per channel for signal (1) typ.: 2.2 mA
  • Output switching design: Power outputs
  • Switching frequency max.: 5 Hz; Ohmsche Last
  • Switching frequency max. (2): 0.1 Hz; Induktive Last nach IEC 947-5-1, DC 13
  • Switching frequency max. (3): 5 Hz; Induktive Last nach IEC 947-5-1, DC 13; mit Freilaufdioden
  • Reactance (max.): capacitive reactance 2 nF; category DC 13
  • Load type of the switching frequency: Ohmsche Last
  • Response times (min ... max) Inputs: t<sub>on</sub> (L->H) = 13 ms 71 ms; t<sub>off</sub> (H->L) = 13 ms 26 ms; plus 2 x K-bus runtime plus 2 x fieldbus runtime plus PLC runtime
  • Response times (max.) Outputs: t<sub>on</sub> (L->H) = 13 ms; t<sub>off</sub> (H->L) = 13 ms; plus 2 x K-bus runtime plus 2 x fieldbus runtime; plus PLC runtime
  • Proof test interval: 10 Years
  • System supply voltage: DC 5 V; via data contacts
  • Current consumption, system supply (5 V): 55 mA
  • Field supply voltage: DC 24 V (-15 +20 %); via power jumper contacts (power supply via blade contact; transmission via spring contact)
  • Isolation: 500 V system/supply
  • Indicators: LED (A-H) green: Status I1 I8; LED (I-K) red: internal, external error
  • Number of incoming power jumper contacts: 2
  • Number of outgoing power jumper contacts: 2
  • Current carrying capacity of the power jumper contacts: 10 A
Connection Data
  • Connection technology: In-/Outputs: 16 x CAGE CLAMP<sup></sup>
  • Connection type (1): Inputs/Outputs
  • Solid conductor: 0.08 2.5 mm / 28 14 AWG
  • Fine-stranded conductor: 0.08 2.5 mm / 28 14 AWG
  • Strip length: 8 9 mm / 0.31 0.35 inch
Geometrical Data
  • Width: 24 mm / 0.945 inch
  • Height: 67.8 mm / 2.669 inch
  • Height from upper-edge of DIN-35 rail: 60.6 mm / 2.386 inch
  • Depth: 100 mm / 3.937 inch
Mechanical Data
  • Type of mounting: DIN-35 rail
Material Data
  • Color: yellow
  • Housing material: Polycarbonate, polyamide 6.6
  • Fire load: 0.000 MJ
  • Weight: 101.193 g
  • Conformity marking: CE
Environmental Requirements
  • Surrounding air (operating) temperature: 0 55 C
  • Surrounding air (storage) temperature: -40 85 C
  • Protection class: IP20
  • Degree of pollution (5): 2 per IEC 61131-2
  • Operating altitude: 0 2000 m
  • Mounting position: horizontal (standing/lying) or vertical
  • Relative air humidity (no condensation): 95 %
  • Vibration resistance: acc. to IEC 60068-2-6
  • Shock resistance: 15g per IEC 60068-2-27
  • EMC immunity to interference: acc. to EN 61000-6-2
  • EMC emission of interference: acc. to EN 61000-6-4
  • Exposure to pollutants: Per IEC 60068-2-42 and IEC 60068-2-43
  • Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 %: 10 ppm
  • Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 %: 25 ppm
Commercial data
  • Packaging type: BOX
  • Country of origin: DE
  • GTIN: 4045454767952
  • Customs Tariff No.: 85389099990
View AllClose