WAGO 750-890/040-000 Modbus TCP Controller with Dual Ethernet Ports and SD Card Slot
WagoThe WAGO 750 XTR series Gen.4 Programmable Logic Controller (PLC) CPU unit is designed for extended temperature ranges from -40°C to +70°C. It features a 32-bit processor, supports up to 64 connections per node, and includes Modbus TCP and Ethernet communication capabilities. The unit operates on a 24Vdc supply voltage and is equipped with two RJ45 connectors for fieldbus and a CAGE CLAMP 2-pin system connector. It mounts on a DIN-35 rail with a width of 61.5mm and includes slots for SD and SDHC cards up to 32GB. Rated at IP20, it replaces the obsolete 750-880/040-000 component and is equivalent to the 750890040000 model.
- baud rate:
- 10/100 Mbit/s
- baud rate communication fieldbus 1:
- 10/100 Mbit/s
- color:
- Dark gray
- communication:
- Modbus (TCP, UDP)
- configuration options:
- WAGO-I/O-CHECK || Web-Based Management || CODESYS Library
- conformity marking:
- CE
- connection technology communication fieldbus:
- Modbus TCP/UDP: 2 x RJ-45
- connection technology device configuration:
- 1 x Male connector: 4-pole
- connection technology field supply:
- 4 x CAGE CLAMP
- connection technology system supply:
- 2 x CAGE CLAMP
- connection type 1:
- System/field supply
- country of origin sales organisation germany:
- DE
- cpu:
- 32 bits
- current carrying capacity power jumper contacts:
- 0.416666666666667
- data memory:
- 8 MB
- depth:
- 71.9 mm / 2.831 inch
- depth from upper edge of din rail:
- 64.7 mm / 2.547 inch
- derating:
- Derating (supply voltage): Surrounding air temperatures under laboratory conditions: (-25 +30 %): for -40 +55 C: 24 V (-25 +20 %): for +55 +70 C: 24 V (-25 +10 %): Lower limit in all temperature ranges: 27.5 % (
- emc emission of interference:
- Per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
- emc immunity to interference:
- Per EN 61000-6-1, -2: EN 61131-2: marine applications: EN 50121-3-2: EN 50121-4, -5: EN 60255-26: EN 60870-2-1: EN 61850-3: IEC 61000-6-5: IEEE 1613: VDEW: 1994
- ethernet protocols:
- HTTP(S) || BootP || DHCP || DNS || SNTP || FTP(S) || SNMP
- exposure to pollutants:
- Per IEC 60068-2-42 and IEC 60068-2-43
- fine stranded conductor:
- 0.25 2.5 mm / 24 14 AWG
- fire load:
- 0.325 MJ
- height:
- 100 mm / 3.937 inch
- housing material:
- Polycarbonate: polyamide 6.6
- indicators:
- LED (LINK/ACT) green: Network connection via ports 1 2: LED (MS, NS) red/green: Status of node, network: LED (I/O, USR) red/green/orange: Local data bus status, status programmable by user: LED (A, B) green: System power supply status, field su
- input and output fieldbus process image max:
- 1020 Worte/1020 Worte
- input current typ at nominal load 24 v:
- 500 mA
- memory card slot:
- Push-push mechanism: Cover lid (sealable)
- memory card type:
- SD and SDHC up to 32 GB (all guaranteed properties only valid with WAGO Memory Card)
- mounting position:
- Horizontal (standing/lying): vertical
- mounting type:
- DIN-35 rail
- non volatile software memory:
- 32 kB
- number of modules per node max:
- 64
- number of outgoing power jumper contacts:
- 2
- operating altitude:
- Without temperature derating: 0 2000 m: with temperature derating: 2000 5000 m (0.5 K/100 m): 5000 m (max.)
- packaging type:
- Box
- permissible h2s contaminant concentration at a relative humidity 75:
- 10 ppm
- permissible so2 contaminant concentration at a relative humidity 75:
- 25 ppm
- pollution degree 5:
- 2 per IEC 61131-2
- power consumption 5 v system supply:
- 440 mA
- power supply efficiency typ at nominal load 24 v:
- 0.9
- program memory:
- 8 MB
- programming environment:
- WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)
- programming languages per iec 61131 3:
- Instruction List (IL) || Ladder Diagram (LD) || Function Block Diagram (FBD), Continuous Function Chart (CFC) || Structured Text (ST) || Sequential Function Chart (SFC)
- protection type:
- IP20
- rated surge voltage:
- 1 kV
- relative humidity with condensation:
- Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
- relative humidity without condensation:
- 0.95
- shock resistance:
- Per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks: 25g/6 ms/1,000 shocks), EN 50155, EN 61373
- solid conductor:
- 0.25 2.5 mm / 24 14 AWG
- strip length:
- 8 9 mm / 0.31 0.35 inch
- supply voltage field:
- 24 VDC: Power supply via pluggable connector (CAGE CLAMP connection): Transmission via power jumper contacts: Derating must be observed!
- supply voltage system:
- 24 VDC: via pluggable connector (CAGE CLAMP connection): Derating must be observed!
- surrounding air temperature operation:
- -40 70 C
- surrounding air temperature storage:
- -40 85 C
- total current system supply:
- 1700 mA
- transmission medium communication fieldbus:
- Twisted Pair S-UTP: 100 : Cat. 5: 100 m maximum cable length
- transmission performance:
- Class D per EN 50173
- vibration resistance:
- Per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155: EN 61373
- visualization:
- Web Visu
- weight:
- 150.621 g
- width:
- 61.5 mm / 2.421 inch