WAGO 855-9450/2000-1251

(No reviews yet) Write a Review
SKU:
855-9450/2000-1251
MPN:
855-9450/2000-1251
Condition:
New
accuracy class:
0.5
cable length:
4.5 m
conformity marking:
CE
country of origin sales organisation germany:
BG
feedthrough for measurement conductor:
125 mm
fire load:
0.000 MJ
limit frequency:
276 kHz
mounting type:
Split-core current transformer (suspended)
mutual inductance m:
72.14 nH
note:
The specifications for the primary rated current refer to a combination with the WAGO Modules (857-552 and 750-495/000-002).Rogowski technology allows the coils to measure a wide primary current range of up to 10,000 A without loss of accuracy, becau
operating altitude max:
2000 m
output signal max:
30 V
packaging type:
Bag
positioning error:
0.75 %
primary rated current:
4000 A (in combination with WAGO products)
rated frequency:
50 60 Hz
rated short time thermal current ith:
300 kA at 50 Hz
relative humidity:
¤ 90% (without condensation)
sensitivity:
22.5 mV/kA at 50 Hz
standards specifications:
EN 61010-1 || EN 61010-2-32 || EN 61869-1 || EN 61869-2 || EN 61869-6 || EN 61869-10 || UL 61010-1
surrounding air temperature operation:
-40 80 C
surrounding air temperature storage:
-40 80 C
voltage for isolation test:
AC 7.4 kV: 50 Hz: 1 min
weight:
130.000 g
  • Wago 855-9450/2000-1251
  • Wago 855-9450/2000-1251
$566.20

Description

Description Rogowski coil; Diameter: 125 mm; Length of signal line: 4.5 m; IP67 degree of protection; Bayonet connector; for cable tie 
Remarks Item description:
Short description:

WAGO's Rogowski coils are closed-air coils featuring a non-magnetic split core that can be connected to a Rogowski Signal Conditioner (857-552).

Easy installation of the Rogowski coils allows existing systems to be retrofitted without time-consuming installation or process interruption.

Rogowski technology allows the coils to measure a wide primary current range without loss of accuracy because there are no saturation effects.

Features:
  • Rated insulation voltage: 1000 V Cat. III/600 V Cat. IV
  • Accuracy class 1 per EN 61869-2
  • IP67 degree of protection
  • Measurement coil diameter: 70, 125 or 175 mm
  • Length of signal lines: 1.5 m or 4.5 m
  • Ambient operating temperature: -40 +80
  • Sealable bayonet connector
  • Fixing lugs for cable ties



Insulation voltage: 1000 Veff AC (Cat. III); 600 Veff AC (Cat. IV)

Output signal voltage: (bei 50 Hz)

 
 
Item properties

Miscellaneous

Name Value Unit
Conformity marking  CE   
Cable length [m]  4.5 
Output signal  22.5 mV/kA at 50 Hz   
Degree of protection  IP67   
Weight [g]  130 
Storage temperature  -40 +80    
Type of mounting  Surrounding conductor (divisible)   
Ambient operating temperature  -40 +80    
Relative humidity  90 %   
View AllClose