SMC EX600 Modular Fieldbus Platform

SMC EX600 Modular Fieldbus Platform

Build a complete valve I/O node on any network. Pick your protocol, add the I/O you need, and complete the manifold - all from one modular, IP67 platform. Shop every EX600 part below, or jump to replacement parts if you are servicing an existing unit.

8+ Network Protocols Up to 1024 I/O Points Up to 9 I/O Units / Manifold IP67 On-Machine Mount SY / JSY / SV / VQC / S0700

The SMC EX600 is a modular fieldbus and valve I/O system that puts solenoid valve outputs, sensor inputs, analog signals, and IO-Link devices onto a single industrial network node. One SI (serial interface) communication unit determines the network protocol; everything else on the manifold is modular and interchangeable. Instead of running every solenoid and sensor wire back to PLC I/O cards in the control cabinet, the EX600 collects them at the machine and passes them through one network cable - cutting wiring, panel space, and commissioning time.

Use the three steps below to build a complete system, or skip to replacement parts if a unit has failed in the field.

STEP 1

Choose Your Protocol (SI Unit)

The SI unit is the brain of the EX600 - it sets the network protocol and is the only protocol-specific part on the manifold. Pick the one that matches your PLC network. PNP (-COM) and NPN (+COM) output versions are available for most protocols.

EtherNet/IP

Current gen: EX600-SEN7 (PNP) / SEN8 (NPN). Dual port, DLR ring, QuickConnect.

Shop EtherNet/IP SI Units

PROFINET

EX600-SPN3 (PNP) / SPN4 (NPN). For Siemens and PROFINET architectures.

Shop PROFINET SI Units

EtherCAT

EX600-SEC1 (PNP) / SEC2 (NPN). For Beckhoff and EtherCAT motion systems.

Shop EtherCAT SI Units

DeviceNet

EX600-SDN1A (PNP). For Allen-Bradley DeviceNet legacy networks.

Shop DeviceNet SI Units

PROFIBUS-DP

EX600-SPR series. For installed PROFIBUS DP plant networks.

Shop PROFIBUS SI Units

CC-Link

EX600-SMJ series. For Mitsubishi CC-Link networks.

Shop CC-Link SI Units

CC-Link IE Field

Gigabit CC-Link IE Field for high-speed Mitsubishi systems.

Shop CC-Link IE SI Units

POWERLINK

EX600-SPL series. For B&R POWERLINK control systems.

Shop POWERLINK SI Units

Wireless (EX600-W)

EX600-WEN1 wireless master. EtherNet/IP over a 2.4 GHz link - no I/O cabling between base and remote.

Shop Wireless Units
STEP 2

Add Your I/O Modules

I/O modules are protocol-independent - the same module works behind any SI unit. Snap up to 9 modules onto one manifold in any combination, for up to 1024 total I/O points.

Digital Input Units (EX600-DX)

Bring auto switches, proximity, photoelectric, and limit switches onto the network node. 8 or 16 channel, PNP or NPN, M12 / M8 (IP67) or D-sub / spring terminal (IP40).

EX600-DXPD (16-ch PNP, M12)  |  EX600-DXPC (8-in PNP, M8)

Digital Output Units (EX600-DY)

Drive solenoids, indicators, and contactors directly from the manifold. 8 or 16 channel, PNP or NPN, M12 / M8 or D-sub.

EX600-DYPB (8-out PNP)  |  EX600-DYPE (16-out PNP)

Digital I/O Combo Units (EX600-DM)

Mixed inputs and outputs on a single module - 8 in / 8 out. Saves a module slot where you need both close together.

EX600-DMPE (8 in / 8 out, D-sub)  |  EX600-DMPF

Analog Units (EX600-A)

Read pressure, flow, temperature, and other 4-20 mA / 0-10 V signals, or send analog outputs - for closed-loop control right at the manifold. Analog in (EX600-AXA), out (EX600-AYA), and combo (EX600-AMB).

Shop EX600 Analog Units

IO-Link Master Modules (EX600-L)

Turn the manifold into an IO-Link master. Up to 4 modules / 16 IO-Link devices per manifold, with automatic parameter download for plug-and-play replacement. Port Class A (EX600-LAB1) and Class B (EX600-LBB1).

EX600-LAB1 (Class A)  |  EX600-LBB1 (Class B)
STEP 3

Complete the Manifold

End plates, valve plate brackets, and accessories that mount the EX600 to your valve manifold and supply power.

End Plates (EX600-ED)

Power-supply end plate that closes the manifold and feeds the system. M12 5-pin B-coded.

Shop EX600-ED2 End Plate

Valve Plate Brackets

Adapter plate that joins the EX600 to your valve manifold. EX600-ZMV2 is matched to the SY series.

Shop EX600-ZMV2 Valve Plate

Handheld Terminal & Accessories

Configure and diagnose the manifold without a PC, plus seal caps, marker plates, and power/comm cables.

Shop EX600 Accessories

How an EX600 System Goes Together

A minimum working EX600 node is just three parts:

1 SI Unit (protocol)  +  1 End Plate (power)  +  1 or more I/O Units

Add a valve plate bracket and SMC valve manifold (SY, JSY, SV, VQC, or S0700) to control solenoids, or run the EX600 as a standalone distributed I/O node with no valves at all. Mix digital, analog, and IO-Link modules in any order, up to 9 units and 1024 I/O points per manifold.

SERVICING AN EXISTING UNIT?

Find Your EX600 Replacement Part

Have a part number off a failed unit? Match it to the right current part below. I/O modules and end plates are direct cross-references; SI units may map to a newer generation.

EtherNet/IP SI unit upgrade: The current-generation EX600-SEN7 (PNP) and EX600-SEN8 (NPN) replace the prior EX600-SEN1/SEN2 (single port) and EX600-SEN3/SEN4 (dual port), adding dual ports, DLR ring redundancy, and QuickConnect. The manifold, I/O modules, and end plates carry over unchanged - only the SI unit changes.

If you have / need Part family Shop
EX600-SEN1 / SEN2 / SEN3 / SEN4 EtherNet/IP SI unit SEN7 / SEN8 →
EX600-SPN_ (PROFINET) PROFINET SI unit SPN3 / SPN4 →
EX600-SEC_ (EtherCAT) EtherCAT SI unit SEC1 / SEC2 →
EX600-DX_ digital input Input module (direct cross) Input units →
EX600-DY_ digital output Output module (direct cross) Output units →
EX600-ED_ end plate End plate (direct cross) End plates →

Not sure which generation you need? Our application engineers can confirm a direct replacement from your existing part number.

EX600 or EX260 - Which Do You Need?

Choose the EX600 when you need a modular node that combines valve outputs with digital inputs, analog I/O, or IO-Link masters on one manifold.

Choose the EX260 when you only need valve output control - it is a compact, lower-cost SI unit (just 28 mm wide) that mounts straight on the valve manifold with no add-on I/O.

Compare the EX260 SI Unit

EX600 Frequently Asked Questions

What is the SMC EX600?

The SMC EX600 is a modular fieldbus and valve I/O platform. A single SI (serial interface) unit connects the manifold to your PLC network, and up to 9 modular I/O units - digital input, digital output, analog, and IO-Link master - snap on in any combination for up to 1024 I/O points. It replaces discrete valve and sensor wiring with one network cable.

How do I choose the right EX600 SI unit?

Choose by network protocol - EtherNet/IP, PROFINET, EtherCAT, PROFIBUS-DP, DeviceNet, CC-Link, CC-Link IE Field, or POWERLINK - and by output polarity (PNP or NPN). The SI unit is the only protocol-specific part; the rest of the manifold stays the same across protocols.

Can I mix I/O modules on one EX600 manifold?

Yes. I/O modules are protocol-independent and mount in any order. One manifold supports up to 9 I/O units in any mix of digital input, digital output, combo, analog, and IO-Link master modules, for up to 1024 total I/O points (512 in / 512 out).

Which valves work with the EX600?

The EX600 is compatible with SMC SY and JSY series, SV1000/2000/3000, VQC1000/2000/4000, and S0700 valve manifolds. A matching valve plate bracket joins the EX600 to the valve base.

My EX600-SEN1 failed - what replaces it?

The current-generation EX600-SEN7 (PNP) or EX600-SEN8 (NPN) replaces the EX600-SEN1, SEN2, SEN3, and SEN4 EtherNet/IP SI units. It adds dual Ethernet ports, DLR ring redundancy, and QuickConnect. Your existing I/O modules and end plate carry over - only the SI unit changes.

Can the EX600 run without valves as standalone I/O?

Yes. With an SI unit, an end plate, and one or more I/O modules, the EX600 works as a distributed I/O node with no valve manifold attached - useful for collecting sensor signals at a point on the machine where there are no valves.

Is the EX600 IP67 rated?

M8 and M12 connector versions are rated IP67 for on-machine mounting without an enclosure. D-sub and spring-terminal versions are rated IP40 and are intended for in-panel use.

Build Your EX600 Node with Automation Distribution

Automation Distribution carries the full SMC EX600 platform - SI units for every protocol, digital and analog I/O, IO-Link masters, end plates, valve plate brackets, and compatible SY, JSY, SV, VQC, and S0700 manifolds. Need help selecting a configuration or confirming a replacement part? Our application engineering team can spec the full assembly from your part number or network requirements.

Contact Application Engineering