Schneider Electric AK5JB146 Bus Bar Tri+N 160Alg664Mm

(No reviews yet) Write a Review
SKU:
AK5JB146
UPC:
3389110588989
Condition:
New
Availability:
Schneider orders under $1250 will incur a $60 processing fee at checkout
Reach Free Of Svhc:
Yes
Number Of Conductors:
4
Flame Retardance:
V0 conforming to UL 94
Mounting Position:
vertical using side stop AK5BT01 on mounting plates AK5PA || horizontal
[Ue] Rated Operational Voltage:
400 V off-load plugging-in and unplugging, with supply switched on)IEC 60439-1 || 480 V off-load plugging-in and unplugging, with supply switched on)CSA || 480 V off-load plugging-in and unplugging, with supply switched on)UL || 600 V plugging-in and
Rohs Exemption Information:
Yes
Network Type:
AC
Enclosure/Cubicle Width:
800 mm
Bar Length:
668 mm
[Ui] Rated Insulation Voltage:
600 V CSA || 600 V UL || 690 V IEC 60439-1
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Width:
81 mm
Protection Type:
aM fuses In = 160 A, Isc = 100 kA, Ie = 160 A || gF fuses In = 160 A, Isc = 100 kA, Ie = 160 A || NS160H circuit breaker In = 160 A, Isc = 36 kA, Ie = 160 A || NS160H circuit breaker In = 160 A, Isc = 70 kA, Ie = 160 A
Product Or Component Type:
busbar
Device Application:
distribution
Product Certifications:
LROS (Lloyds register of shipping) || DNV || UL || CSA
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Toxic Heavy Metal Free:
Yes
Ip Degree Of Protection:
IPxx B conforming to IEC 60529
I²T On Activation:
10000000 A².s
Tightening Torque:
10 N.m
Fire Resistance:
850 °C IEC 60695
Warranty:
18 months
Peak Current:
25 kA
Depth:
82 mm
Number Of Tap-Offs:
30
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Range:
Linergy
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Net Weight:
1.3 kg
Standards:
IEC 60439
Connections - Terminals:
connector 2.5-70 mm² flexible with cable end || connector 2.5-70 mm² rigid
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Circularity Profile:
N/A
Network Frequency:
50/60 Hz
[Ie] Rated Operational Current:
160 A 35 °C
Environmental Disclosure:
ENVPEP120206EN
Eu Rohs Directive:
Compliant
Product Name:
HK
Bar Width:
45 mm
$345.00

Description

Busbars can be screw-mounted onto any type of support. If the busbar is to be used with component mounting plates with a tap-off, it is essential that the bus bar is mounted on the AM1DL201 DIN mounting rail. This 4 conducor bus bar system has 30 tap offs at 18 mm intervals. The busbar system is 26.3 inches (668 mm) long. Bus bar system is rated 160 A at 600 VAC. The bus bar system is 26.30 inches long, 3.19 inches wide and 3.23 inches deep. Each wieghs 0.41 oz. The busbar system is UL Listed, CSA certified and meet IEC requirements.
View AllClose