Schneider Electric AK5JB1410 Bus Bar Tri 160A Lg1096Mm

(No reviews yet) Write a Review
SKU:
AK5JB1410
UPC:
3.38911E+12
Condition:
New
Availability:
Schneider orders under $1250 will incur a $60 processing fee at checkout
Warranty:
18 months
Sustainable Offer Status:
Green Premium product
Connections - Terminals:
connector 2.5-70 mm² flexible with cable end || connector 2.5-70 mm² rigid
Mounting Position:
vertical using side stop AK5BT01 on mounting plates AK5PA || horizontal
Circularity Profile:
N/A
Product Name:
HK
Depth:
82 mm
Tightening Torque:
10 N.m
Ip Degree Of Protection:
IPxx B conforming to IEC 60529
Mercury Free:
Yes
Network Type:
AC
[Ui] Rated Insulation Voltage:
600 V CSA || 600 V UL || 690 V IEC 60439-1
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Net Weight:
2.1 kg
[Ie] Rated Operational Current:
160 A 35 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc:
Yes
Flame Retardance:
V0 conforming to UL 94
Rohs Exemption Information:
Yes
Product Or Component Type:
busbar
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Standards:
IEC 60439
Number Of Conductors:
4
Bar Width:
45 mm
Enclosure/Cubicle Width:
1200 mm
Eu Rohs Directive:
Compliant
Number Of Tap-Offs:
54
Environmental Disclosure:
ENVPEP120206EN
I²T On Activation:
10000000 A².s
Device Application:
distribution
Product Certifications:
UL || LROS (Lloyds register of shipping) || DNV || CSA
Protection Type:
aM fuses In = 160 A, Isc = 100 kA, Ie = 160 A || gF fuses In = 160 A, Isc = 100 kA, Ie = 160 A || NS160H circuit breaker In = 160 A, Isc = 36 kA, Ie = 160 A || NS160H circuit breaker In = 160 A, Isc = 70 kA, Ie = 160 A
Fire Resistance:
850 °C IEC 60695
Bar Length:
1100 mm
Peak Current:
25 kA
Width:
81 mm
Range:
Linergy
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Toxic Heavy Metal Free:
Yes
[Ue] Rated Operational Voltage:
400 V off-load plugging-in and unplugging, with supply switched on)IEC 60439-1 || 480 V off-load plugging-in and unplugging, with supply switched on)CSA || 480 V off-load plugging-in and unplugging, with supply switched on)UL || 600 V plugging-in and
Network Frequency:
50/60 Hz
  • Schneider Electric AK5JB1410 Bus Bar Tri 160A Lg1096Mm
  • Schneider Electric AK5JB1410 Bus Bar Tri 160A Lg1096Mm
$540.00