Schneider Electric ATV630D11S6X Atv630 Ip21 15Hp 600V Variateur De Vit.
SKU:
ATV630D11S6X
UPC:
3.60648E+12
MPN:
Condition:
New
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Pollution Degree:
2
Number Of Addresses:
1-247 Modbus serial
Maximum Horse Power Rating:
15 hp 600 V normal duty || 10 hp 600 V heavy duty
Ip Degree Of Protection:
IP21IEC 61800-5-1 || IP21IEC 60529
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Product Destination:
asynchronous motors || synchronous motors
[Us] Rated Supply Voltage:
600 V - 15...10 %
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Maximum Output Frequency:
500 kHz
Supply Frequency:
50...60 Hz - 5...5 %
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
China Rohs Regulation:
X
Switching Frequency:
2...12 kHz adjustable || 4...12 kHz with derating factor
Pollution Degree:
2 IEC 61800-5-1
Continuous Output Current:
18 A 4 kHz normal duty || 13.5 A 4 kHz heavy duty
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range Of Product:
Altivar Process ATV600
Degree Of Protection:
UL type 1 UL 508C
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Operating Position:
vertical +/- 10 degree
Speed Drive Output Frequency:
0.1-500 Hz
Height:
409 mm
Output Voltage:
<= power supply voltage
Power Dissipation In W:
natural convection 114 W 600 V 4 kHz || forced convection 152 W 600 V 4 kHz
Braking To Standstill:
by DC injection
Data Format:
8 bits, configurable odd, even or no parity
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Circularity Profile:
ENVEOLI1707007EN
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Product Certifications:
TÃV || UL || CSA
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Width:
171 mm
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Ambient Air Temperature For Storage:
-40-70 °C
Analogue Input Number:
3
Phase:
3 phase
Motor Slip Compensation:
automatic whatever the load || can be suppressed || not available in permanent magnet motor law || adjustable
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Noise Level:
52 dB 86/188/EEC
Overvoltage Category:
III
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 6...10 mm² AWG 10...AWG 8 || line side screw terminal 6...10 mm² AWG 10...AWG 8
Communication Port Protocol:
Modbus TCP || Ethernet || Modbus serial
Product Or Component Type:
variable speed drive
Type Of Polarization:
no impedance
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Physical Interface:
Ethernet || 2-wire RS 485
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s || S, U or customized
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Method Of Access:
slave Modbus TCP
Prospective Line Isc:
70 kA
Maximum Transient Current:
19.8 A 60 s normal duty) || 20.3 A 60 s heavy duty)
Apparent Power:
15.9 kVA 600 V normal duty) || 11.5 kVA 600 V heavy duty)
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
[Us] Rated Supply Voltage:
600 V
Enclosure Mounting:
wall mounted
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m