Schneider Electric

Schneider Electric ATV630D55N4 Variable Speed Drive Ip21 55Kw 400V/480V

(No reviews yet) Write a Review
SKU:
ATV630D55N4
UPC:
3606480701443
Condition:
New
Transmission Frame:
RTU
Discrete Input Logic:
16 preset speeds
Sustainable Offer Status:
Green Premium product
Variant:
standard version
Discrete Output Number:
0
Supply Frequency:
50...60 Hz - 5...5 %
Braking To Standstill:
by DC injection
Maximum Horse Power Rating:
75 hp normal duty || 60 hp heavy duty
Discrete And Process Manufacturing:
building - HVAC compressor centrifugal || food and beverage processing other application || mining mineral and metal fan || mining mineral and metal pump || oil and gas fan || water and waste water other application || building - HVAC screw compresso
Marking:
CE
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Analogue Output Number:
2
Isolation:
between power and control terminals
Noise Level:
62.4 dB 86/188/EEC
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Power Range:
55-100 kW 380-440 V 3 phase || 55-100 kW 480-500 V 3 phase
Enclosure Mounting:
wall mounted
Type Of Cooling:
forced convection
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Product Destination:
asynchronous motors || synchronous motors
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Height:
922 mm
China Rohs Regulation:
X
Product Or Component Type:
variable speed drive
Analogue Input Number:
3
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Emc Filter:
integrated 150 m EN/IEC 61800-3 category C3
Speed Drive Output Frequency:
0.1-500 Hz
Data Format:
8 bits, configurable odd, even or no parity
[Us] Rated Supply Voltage:
380...480 V
Net Weight:
56.5 kg
Rohs Exemption Information:
Yes
Type Of Polarization:
no impedance
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Noise Level:
62.4 dB
Volume Of Cooling Air:
295 m3/h
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Pollution Degree:
2
Motor Power Kw:
55 kW normal duty) || 45 kW heavy duty)
Power Dissipation In W:
natural convection 131 W 380 V 2.5 kHz || forced convection 917 W 380 V 2.5 kHz
Circularity Profile:
ENVEOLI1411014EN
Asynchronous Motor Control Profile:
constant torque standard || variable torque standard || optimized torque mode
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Ambient Air Temperature For Storage:
-40-70 °C
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Motor Slip Compensation:
not available in permanent magnet motor law || can be suppressed || automatic whatever the load || adjustable
Maximum Output Frequency:
500 kHz
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Relay Output Number:
3
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 70...120 mm² AWG 1/0...250 kcmil || motor screw terminal 70...120 mm² AWG 1/0...250 kcmil
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Degree Of Protection:
UL type 1 UL 508C
Phase:
3 phase
Line Current:
97.2 A 380 V normal duty) || 84.2 A 480 V normal duty) || 81.4 A 380 V heavy duty) || 71.8 A 480 V heavy duty)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Discrete Input Number:
8
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Output Voltage:
<= power supply voltage
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environmental Disclosure:
ENVPEP1411014EN
Safety Function:
STO (safe torque off) SIL 3
Quantity Per Set:
1
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Regulation Loop:
adjustable PID regulator
Width:
290 mm
Depth:
323 mm
Nominal Switching Frequency:
2.5 kHz
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Product Certifications:
CSA || UL || DNV-GL || ATEX INERIS || ATEX zone 2/22 || TÜV
Continuous Output Current:
106 A 2.5 kHz normal duty || 88 A 2.5 kHz heavy duty
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Mercury Free:
Yes
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Ip Degree Of Protection:
IP21IEC 61800-5-1 || IP21IEC 60529
Prospective Line Isc:
50 kA
Communication Port Protocol:
Ethernet || Modbus serial || Modbus TCP
Apparent Power:
70 kVA 480 V normal duty) || 59.7 kVA 480 V heavy duty)
Input Compatibility:
DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
Physical Interface:
Ethernet || 2-wire RS 485
Number Of Addresses:
1-247 Modbus serial
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Range Of Product:
Altivar Process ATV600
Pollution Degree:
2 EN/IEC 61800-5-1
Device Short Name:
ATV630
Overvoltage Category:
III
Mounting Mode:
wall mount
Upgradeability:
Upgraded components available
Standards:
UL 508C || EN/IEC 61800-3 || EN/IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Operating Position:
vertical +/- 10 degree
Switching Frequency:
2.5...8 kHz with derating factor || 2...8 kHz adjustable
Maximum Transient Current:
116.6 A 60 s normal duty) || 132 A 60 s heavy duty)
Method Of Access:
slave Modbus TCP
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Product Specific Application:
process and utilities
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Brochure:
View
Catalog:
View
Datasheet:
View
$10,856.75

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 480V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 55kW / 75hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 45kW / 60hp for applications requiring significant overload (up to 150%). It weighs 56.5kg and its dimensions are, 290mm wide, 922mm high, 323mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose