Schneider Electric ATV930D18M3 Atv930 Ip21 18Kw 200V/240V Variable Spee

(No reviews yet) Write a Review
SKU:
ATV930D18M3
UPC:
3606480883637
Condition:
New
With Safety Function Safe Programmable Logic:
FALSE
Base Load Current At Low Overload:
78.4 A
Width:
226 mm
Discrete Input Number:
10
Range Of Product:
Altivar Process ATV900
Product Or Component Type:
variable speed drive
China Rohs Regulation:
X
Analogue Input Number:
3
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Connector Type:
2 RJ45 || 1 RJ45
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Quantity Per Set:
1
Apparent Power:
22.7 kVA 240 V normal duty) || 18.7 kVA 240 V heavy duty)
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Power Dissipation In W:
natural convection 97 W 200 V 4 kHz || forced convection 595 W 200 V 4 kHz
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
With Safety Function Safely Limited Position (Slp):
FALSE
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Ambient Air Temperature For Storage:
-40-70 °C
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Type Of Polarization:
no impedance
Braking To Standstill:
by DC injection
Variant:
standard version || with braking chopper
Sustainable Offer Status:
Green Premium product
Volume Of Cooling Air:
240 m3/h
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Environmental Disclosure:
ENVPEP1411001EN
Relay Output Number:
3
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Analogue Output Number:
2
Overvoltage Category:
III
Motor Slip Compensation:
automatic whatever the load || adjustable || can be suppressed || not available in permanent magnet motor law
Depth:
274 mm
Number Of Addresses:
1-247 Modbus serial
With Safety Function Safe Torque Off (Sto):
TRUE
Ip Degree Of Protection:
IP21
Data Format:
8 bits, configurable odd, even or no parity
Product Certifications:
UL || TÜV || CSA
Maximum Output Frequency:
599 Hz
Number Of Addresses:
1-247
With Safety Function Safe Direction (Sdi):
FALSE
Phase:
3 phase
Prospective Line Isc:
50 kA
Circularity Profile:
ENVEOLI1411001EN
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Upgradeability:
Upgraded components available
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Method Of Access:
slave Modbus TCP
Base Load Current At High Overload:
63.4 A
With Safety Function Safe Operating Stop (Sos):
FALSE
Operating Position:
vertical +/- 10 degree
Product Specific Application:
process for industrial
Physical Interface:
Ethernet || 2-wire RS 485
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Brake Chopper Integrated:
TRUE
Pollution Degree:
2
Discrete Input Logic:
16 preset speeds
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mounting Mode:
wall mount
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Type Of Polarization:
no impedance Modbus serial
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Height:
673 mm
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Net Weight:
27.3 kg
Maximum Transient Current:
94.1 A 60 s normal duty) || 95.1 A 60 s heavy duty)
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Maximum Output Voltage:
240.0 V
Line Current:
66.7 A 200 V normal duty) || 53.1 A 200 V heavy duty) || 54.5 A 240 V normal duty) || 44.9 A 240 V heavy duty)
Communication Port Protocol:
EtherNet/IP || Modbus TCP || Modbus serial
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Transmission Frame:
RTU
Network Frequency:
50-60 Hz
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Isolation:
between power and control terminals
4 Quadrant Operation Possible:
TRUE
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || DC bus screw terminal 25...50 mm² AWG 4...AWG 1 || line side screw terminal 35...50 mm² AWG 3...AWG 1 || motor screw terminal 35...50 mm² AWG 3...AWG 1
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Discrete Output Number:
2
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Assembly Style:
enclosed
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Marking:
CE
With Safety Function Safe Stop 1 (Ss1):
TRUE
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Emc Filter:
integrated || with EMC plate option
[Us] Rated Supply Voltage:
200...240 V - 15...10 %
Asynchronous Motor Control Profile:
variable torque standard || optimized torque mode || constant torque standard
Motor Power Kw:
18.5 kW normal duty || 15.0 kW heavy duty
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Relative Symmetric Network Frequency Tolerance:
0.05
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Noise Level:
71.5 dB
Continuous Output Current:
78.4 A 4 kHz normal duty || 63.4 A 4 kHz heavy duty
Regulation Loop:
adjustable PID regulator
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
With Safety Function Safely Limited Speed (Sls):
TRUE
Ambient Air Transport Temperature:
-40-70 °C
With Safety Function Safe Position (Sp):
FALSE
Noise Level:
71.5 dB 86/188/EEC
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Device Application:
Industrial Application
Degree Of Protection:
UL type 1
Product Destination:
asynchronous motors || synchronous motors
Nominal Switching Frequency:
4 kHz
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric ATV930D18M3 Atv930 Ip21 18Kw 200V/240V Variable Spee
  • Schneider Electric ATV930D18M3 Atv930 Ip21 18Kw 200V/240V Variable Spee
  • Schneider Electric ATV930D18M3 Atv930 Ip21 18Kw 200V/240V Variable Spee
$5,470.61

Description

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 18.5kW/25HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 15kW/20HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 200Vac to 240Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments: oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
View AllClose