PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 50A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Depth:
- 89 mm
- Line Rated Current:
- 50-50 A
- Mounting Mode:
- I-Line
- Height:
- 137 mm
- Device Application:
- distribution
- Standards:
- NEMA AB1 || NMX J-266 || UL 489 || EN/IEC 60947-2 || GB 14048.2 || EN/IEC 60947-5-1 || CSA C22.2 No 5
- Eu Rohs Directive:
- Compliant with Exemptions
- Circuit Breaker Application:
- HACR rated
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Sustainable Offer Status:
- Green Premium product
- Color:
- Gray RAL 7016)
- Connection Pitch:
- 27 mm
- Suitability For Isolation:
- yes IEC 60947-2
- Quality Labels:
- CE
- Ambient Air Temperature For Storage:
- -50-85 °C
- Quantity Per Set:
- set of 1
- Local Signalling:
- presence of auxiliary contacts flag green)
- Electrical Connection:
- I-Line connection, line || lugs, load
- Device Short Name:
- BG 050
- Width:
- 54 mm
- Circularity Profile:
- N/A
- Mercury Free:
- Yes
- Trip Unit Technology:
- thermal-magnetic
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Pvc Free:
- Yes
- Control Type:
- toggle
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
- Continuous Current Rating:
- 0.8
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Mounting Height:
- 76.2 mm
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Product Name:
- PowerPact B
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- [Ue] Rated Operational Voltage:
- 525 V AC 50/60 Hz UL 489
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Range:
- PowerPact
- Ik Degree Of Protection:
- IK07 IEC 62262
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Phase Connection:
- AB
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Rohs Exemption Information:
- Yes
- Utilisation Category:
- category A
- Breaking Capacity:
- 65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 250 V DC UL 489 || 20 kA 600Y/347 V AC 50/60 Hz UL 489
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Ambient Air Temperature For Operation:
- -25-70 °C
- Network Frequency:
- 50/60 Hz
- Product Or Component Type:
- circuit breaker
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Halogen Content Performance:
- Halogen free product
- Pollution Degree:
- 3 IEC 60947-1
- Poles Description:
- 2P
- Net Weight:
- 0.952 kg
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Wire Stripping Length:
- 20 mm
- Breaking Capacity Code:
- G
- 9 Mm Pitches:
- 6
- Environmental Disclosure:
- ENVPEP1610005EN
- Brochure:
- View
- Catalog:
- View
- Datasheet: